7132/2-2

Eksport: PDF ikon PDF
  • Generell informasjon

    Generell informasjon
    Attributt Verdi
    Brønnbane navn
    Offisielt navn på brønnbanen ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    7132/2-2
    Type
    Brønnbanetype. Lovlige verdier: EXPLORATION, DEVELOPMENT, OTHER (se 'Formål' for mer informasjon)
    EXPLORATION
    Formål
    Endelig klassifisering av brønnbanen.

    Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Lovlige verdier for utvinningsbrønnbaner:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Lovlig verdier for andre brønnbaner:
    SOIL DRILLING (boring ifm trase og andre grunnundersøkelser som gjøres for å undersøke grunnforholdene i forkant av plassering av innretninger),
    SHALLOW GAS (undersøke grunn gass før første boring på lokasjon),
    PILOT (undersøke geologi og væskekontakter for plassering av hovedbrønnbanen),
    SCIENTIFIC (bores ihhtLov om vitenskapelige undersøkelser),
    STRATIGRAPHIC (bores ihht Petroleumsloven §2-1).
    WILDCAT
    Status
    Status for brønnbanen. Lovlige verdier:

    BLOWOUT: Det har vært blowout i brønnen.
    CLOSED: Utvinningsbrønnbane som er stengt for produksjon/injeksjon i kortere eller lengre periode. Statusen er også brukt på ferdig borete brønnbaner, der månedlig produksjon/injeksjon ikke har blitt rapportert enda.
    DRILLING: Brønnen er i borefasen. Kan være i aktiv boring, logging, testing eller plugging.
    JUNKED: Boringen ble avsluttet pga tekniske problemer,
    P&A: For letebrønnbane: brønnbanen er plugget og forlatt, og kan ikke re-entres for videre bruk. For utvinningsbrønnbane: produksjon/injeksjon er avsluttet og brønnen er plugget. Brønnhodet er fjernet eller på annet vis gjort utilgjengelig for nye brønnoperasjoner.
    PLUGGED: Brønnbane som er plugget, men øvre deler av brønnbanen kan brukes til å bore nye sidesteg mot nye boremål.
    PRODUCING: Det ble produsert fra brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    INJECTING: Det ble injisert i brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    SUSPENDED: Brønnbane der boringen er midlertidig stoppet. Rettighetshaverne planlegger å fortsette boringen på et senere tidspunkt.
    WILL NEVER BE DRILLED: Brønnbane som er registrert med navn og WellID av Sokkeldirektoratet, men som av ulike årsaker ikke vil bli boret.
    P&A
    Pressemelding
    Flergrensbønn
    Indikator som forteller om brønnbanen er en flergrensbrønn, dvs. har mer enn en gren. Eksempel på lovlige verdier: YES, NO. Se også Sokkeldirektoratets retninglinjer for betegnelse på brønner og brønnbaner.
    NO
    Faktakart i nytt vindu
    Hovedområde
    Navn på området på norsk koninentalsokkel hvor brønnbanen ligger. Lovlige verdier: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    BARENTS SEA
    Brønn navn
    Offisielt navn på brønnen som brønnbanen tilhører ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    7132/2-2
    Utvinningstillatelse
    Offisielt navn på utvinningstillatelsen som brønnbanen ble boret eller planlegges boret ut fra (brønnhodeposisjonen).
    Boreoperatør
    Navn på rettighetshaver som på vegne av den aktive utvinningstillatelsen (ved brønnhodeposisjon) starter boreoperasjonen. Dette tilsvarer vanligvis operatørselskapet for den aktuelle utvinningstillatelsen.
    Equinor Energy AS
    Boretillatelse
    Boretillatelsesnummer sammen med versjon av boretillatelsen som angitt i boretillatelsen gitt av Sokkeldirektoratet.
    1743-L
    Boreinnretning
    Sokkeldirektoratets navn på innretningen som brønnbanen ble boret fra.
    Boredager
    Antall dager fra borestart til boreslutt.
    63
    Borestart
    Dato borekrona trengte gjennom jordskorpa. For sidesteg: Datoen ny formasjon blir boret, se også utboringsdyp.
    06.01.2019
    Boreslutt
    Letebrønner fra flyttbare innretninger:
    For flytende innretninger - dato når ankerhåndteringen startet.For oppjekkbare innretninger - dato for oppstart av nedjekking.
    Letebrønner fra faste innretninger og alle utvinningsbrønner:
    Dato for når totalt dyp er nådd og siste foringsrør, casing eller screen er satt. Ved umiddelbar plugging av brønnbanen, tilsvarer boreslutt datoen siste plugg er satt.
    07.04.2019
    Frigitt dato
    Dato for når rådata som er innrapportert til myndighetene fra brønnen ikke lenger er undergitt taushetsplikt. Normalt ca 2 år etter boreslutt. Kan være tidligere hvis arealet for utvinningstillatelsen er tilbakelevert.
    01.07.2020
    Plugget og forlatt dato
    Dato P&A-operasjonen av brønnbanen var ferdig, som innmeldt av operatør til DDRS (Daily Drilling Reporting System). Forekommer bare en gang pr. brønnhode/overflateposisjon.
    07.04.2019
    Publiseringsdato
    Dato kvalitetskontroll av informasjon om brønnbanen ble ferdig, slik at den kan publiseres på internett som en 'Well Data Summary Sheet brønnbane', dvs. med mer informasjon tilgjengelig enn for andre brønnbaner.
    03.05.2021
    Opprinnelig formål
    Formålet med brønnbanen definert før borestart.Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Eksempler på lovlige verdier for utvinningsbrønnbaner: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Innhold
    For letebrønnbaner, funn status.

    Lovlige verdier: DRY, SHOWS (spor av hydrokarboner), GAS, GAS/CONDENSATE, OIL eller OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS eller OIL/GAS SHOWS) er oppdaget som fluorescerende kutt (organisk ekstrakt), lukt av petroleum, eller synlig belegg på borekaks eller borekjerner, eller som økte gassavlesninger i slamloggerens detekteringsutstyr.
    Lovlige verdier for WILDCAT-CCS og APPRAISAL-CCS: WATER

    For utvinningsbrønnbaner, type produsert eller injisert fluid.
    Lovlige verdier: WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    DRY
    Funnbrønnbane
    Indikator som forteller om brønnbanen påviste et nytt funn. Lovlige verdier: YES, NO. For brønnbaner der resultatet ikke er pressemeldt eller på annet vis avklart, blir «NO» benyttet.
    NO
    Avstand, boredekk - midlere havflate [m]
    Avstand i meter mellom boredekk og midlere havnivå (RKB).
    31.0
    Vanndybde ved midlere havflate [m]
    Dybde i meter mellom midlere havflate og havbunn.
    304.0
    Totalt målt dybde (MD) [m RKB]
    Målt lengde av brønnbanen fra boredekket til bunnen av brønnbanen ("driller`s depth").
    3528.0
    Totalt vertikalt dybde (TVD) [m RKB]
    Vertikalt dybde fra dypet ved slutten av brønnbanen til boredekket. Vises bare på brønner som er frigitt. Referert til som sant vertikalt dyp (TVD: TrueVerticalDepth).
    3527.0
    Eldste penetrerte alder
    Alder (iflg. Geologic Time Scale 2004 by F. M. Gradstein, et al. (2004)) til den eldste formasjonen det er blitt boret gjennom. Kan avvike fra alder ved TD for eksempel i avviksbrønner. Eksempler for lovlige verdier: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EARLY PERMIAN, EARLY TRIASSIC, EOCENE.
    LATE PERMIAN
    Eldste penetrerte formasjon
    Navn på den eldste litostratigrafiske enheten som brønnbanen har penetrert. Vises bare på brønner som er frigitt. I de fleste brønnbaner er dette formasjonen eller gruppen påtruffet i bunnen av brønnbanen. Kan avvike fra formasjonen eller gruppen ved TD for eksempel i brønnbaner som er boret med høy avvik eller gjennom forkastninger. Eksempler på lovlige verdier: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, SHETLAND GP.
    RØYE FM
    Geodetisk datum
    Referansesystem for koordinater. Eksempel på lovlige verdier: ED50.
    ED50
    NS grader
    Geografisk koordinat for brønnhode, nord-sør grader.
    71° 50' 28.37'' N
    ØV grader
    Geografisk koordinat for brønnhode, øst-vest grader.
    32° 23' 17.84'' E
    NS UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, nord-sør.
    7971546.00
    ØV UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, øst-vest.
    478721.28
    UTM sone
    Universal Transverse Mercator sone. Eksempel på lovlige verdier: 31, 32, 33, 34.
    36
    NPDID for brønnbanen
    Sokkeldirektoratets entydige nøkkel for brønnbanen.
    8638
  • Brønnhistorie

    General
    Well 7132/2-2 was drilled to test the Gjøkåsen Deep prospect on the Signalhornet Dome on the Finmark Platform in the Barents Sea. The Gjøkåsen Deep is the second well on the structure; it was planned and drilled back-to-back with the first well, 7132/2-1 Gjøkåsen. The primary exploration target for Gjøkåsen Deep was to prove petroleum in reservoir rocks from the Early to Late Triassic Age (the Snadd, Kobbe and Havert formation). The secondary exploration target was to prove petroleum and reservoir potential in the lower Havert formation (Early Triassic Age).
    Operations and results
    Wildcat well 7132/2-2 was spudded with the semi-submersible installation West Hercules on 6 January 2019 and drilled to TD at 3528 m in the Permian Røye Formation. After drilling the top hole to 600 m the well was suspended from 14 January to 9 February when the rig was engaged in operations at 7132/2-1. An influx was registered by high gas readings at surface while circulating bottoms up from TD at 3400 m, with a gas peak of 52.3% before the well was shut in. No volume increase was observed in the active system. The well was drilled with seawater and hi-vis sweeps down to 601 m, with KCl/polymer/GEM mud from 601 to 1851 m, and with Innovert oil-based mud from 1851 m to TD.
    In the primary exploration target, well 7132/2-2 encountered 25 metres of sandstone reservoir with moderate to good quality in the Snadd formation (Carnian Age), 17 metres of sandstone reservoir with poor to moderate quality in the Kobbe formation and 26 metres of sandstone reservoir with poor quality in the upper Havert formation. Sandstone reservoir was also encountered in the Klappmyss Formation (Early Triassic Age) in a thickness of 17 metres with poor quality. In the secondary exploration target in the lower Havert Formation, the well encountered an interval of approximately 110 metres of sandstones with very poor reservoir quality. High measurements of formation gas with heavier hydrocarbons in the interval 3215 to 3400 m in Havert led to an extension of the well. The objective of the extension was to evaluate potential presence of source rock and underlying reservoir rocks in the Early Triassic and Late Permian (the Ørret and Røye formation). No reservoir rocks were encountered in this interval. The well is dry. Direct fluorescence (no cut, no residue) at several levels in the well was interpreted as mineral fluorescence.
    No cores were cut. MDT water samples were taken at 1915.5 m in the Havert Formation. The samples were contaminated with 42% to 71% oil-based mud.
    The well was permanently abandoned on 7 April 2019 as a dry well.
    Testing
    No drill stem test was performed.
  • Borekaks i Sokkeldirektoratet

    Borekaks i Sokkeldirektoratet
    Borekaks tilgjengelig for prøvetaking?
    YES
    Borekaks i Sokkeldirektoratet
    Borekaksprøve, topp dybde [m]
    Borekaksprøve, bunn dybde [m]
    603.00
    3393.00
  • Foringsrør og formasjonsstyrketester

    Foringsrør og formasjonsstyrketester
    Type utforing
    Utforing diam.
    [tommer]
    Utforing dybde
    [m]
    Brønnbane diam.
    [tommer]
    Brønnbane dyp
    [m]
    LOT/FIT slam eqv.
    [g/cm3]
    Type formasjonstest
    CONDUCTOR
    36
    385.9
    41
    388.2
    0.00
    SURF.COND.
    20
    594.6
    26
    601.0
    1.39
    FIT
    INTERM.
    13 3/8
    952.6
    17 1/2
    962.0
    1.50
    FIT
    LINER
    9 5/8
    1849.0
    12 1/4
    1851.0
    1.83
    LOT
    LINER
    7
    3144.3
    8 1/2
    3400.0
    1.61
    FIT
    OPEN HOLE
    3528.0
    6
    3528.0
    0.00
  • Logger

    Logger
    Type logg
    Topp dyp for logg [m]
    Bunn dyp for logg [m]
    0
    0
  • Litostratigrafi

  • Boreslam

    Boreslam
    Dybde MD [m]
    Egenvekt, slam [g/cm3]
    Viskositet, slam [mPa.s]
    Flytegrense [Pa]
    Type slam
    Dato, måling
    379
    1.35
    25.0
    KCl/Polymer/GEM
    500
    1.03
    1.0
    Seawater
    595
    1.14
    17.0
    KCl/Polymer/GEM
    601
    1.35
    25.0
    KCl/Polymer/GEM
    612
    1.14
    17.0
    KCl/Polymer/GEM
    1035
    1.14
    21.0
    KCl/Polymer/GEM
    1766
    1.15
    17.0
    KCl/Polymer/GEM
    1766
    1.14
    593.0
    KCl/Polymer/GEM
    1818
    1.14
    18.0
    Innovert
    1851
    1.15
    18.0
    KCl/Polymer/GEM
    1860
    1.14
    18.0
    Innovert
    2944
    1.37
    20.0
    Innovert
    3020
    1.14
    14.0
    Innovert
    3079
    1.37
    21.0
    Innovert
    3131
    1.14
    14.0
    Innovert
    3148
    1.37
    21.0
    Innovert
    3150
    1.28
    17.0
    Innovert
    3150
    1.32
    21.0
    Innovert
    3240
    1.14
    18.0
    Innovert
    3400
    1.28
    17.0
    Innovert
    3400
    1.14
    16.0
    Innovert
    3419
    1.37
    20.0
    Innovert
    3528
    1.37
    21.0
    Innovert
  • Palynologiske preparater i Sokkeldirektoratet

    Palynologiske preparater i Sokkeldirektoratet
    Prøve dybde
    Dybde enhet
    Prøve type
    Laboratorie
    606.0
    [m]
    DC
    CGG
    615.0
    [m]
    DC
    CGG
    624.0
    [m]
    DC
    CGG
    633.0
    [m]
    DC
    CGG
    642.0
    [m]
    DC
    CGG
    651.0
    [m]
    DC
    CGG
    660.0
    [m]
    DC
    CGG
    669.0
    [m]
    DC
    CGG
    678.0
    [m]
    DC
    CGG
    687.0
    [m]
    DC
    CGG
    696.0
    [m]
    DC
    CGG
    705.0
    [m]
    DC
    CGG
    711.0
    [m]
    DC
    CGG
    717.0
    [m]
    DC
    CGG
    723.0
    [m]
    DC
    CGG
    729.0
    [m]
    DC
    CGG
    735.0
    [m]
    DC
    CGG
    741.0
    [m]
    DC
    CGG
    747.0
    [m]
    DC
    CGG
    750.0
    [m]
    DC
    CGG
    753.0
    [m]
    DC
    CGG
    756.0
    [m]
    DC
    CGG
    759.0
    [m]
    DC
    CGG
    762.0
    [m]
    DC
    CGG
    768.0
    [m]
    DC
    CGG
    774.0
    [m]
    DC
    CGG
    780.0
    [m]
    DC
    CGG
    789.0
    [m]
    DC
    CGG
    798.0
    [m]
    DC
    CGG
    807.0
    [m]
    DC
    CGG
    816.0
    [m]
    DC
    CGG
    825.0
    [m]
    DC
    CGG
    834.0
    [m]
    DC
    CGG
    843.0
    [m]
    DC
    CGG
    852.0
    [m]
    DC
    CGG
    861.0
    [m]
    DC
    CGG
    870.0
    [m]
    DC
    CGG
    879.0
    [m]
    DC
    CGG
    888.0
    [m]
    DC
    CGG
    897.0
    [m]
    DC
    CGG
    906.0
    [m]
    DC
    CGG
    915.0
    [m]
    DC
    CGG
    924.0
    [m]
    DC
    CGG
    933.0
    [m]
    DC
    CGG
    942.0
    [m]
    DC
    CGG
    951.0
    [m]
    DC
    CGG
    960.0
    [m]
    DC
    CGG
    969.0
    [m]
    DC
    CGG
    978.0
    [m]
    DC
    CGG
    987.0
    [m]
    DC
    CGG
    996.0
    [m]
    DC
    CGG
    1005.0
    [m]
    DC
    CGG
    1014.0
    [m]
    DC
    CGG
    1023.0
    [m]
    DC
    CGG
    1032.0
    [m]
    DC
    CGG
    1041.0
    [m]
    DC
    CGG
    1050.0
    [m]
    DC
    CGG
    1059.0
    [m]
    DC
    CGG
    1068.0
    [m]
    DC
    CGG
    1077.0
    [m]
    DC
    CGG
    1086.0
    [m]
    DC
    CGG
    1095.0
    [m]
    DC
    CGG
    1104.0
    [m]
    DC
    CGG
    1113.0
    [m]
    DC
    CGG
    1122.0
    [m]
    DC
    CGG
    1131.0
    [m]
    DC
    CGG
    1140.0
    [m]
    DC
    CGG
    1149.0
    [m]
    DC
    CGG
    1158.0
    [m]
    DC
    CGG
    1167.0
    [m]
    DC
    CGG
    1176.0
    [m]
    DC
    CGG
    1194.0
    [m]
    DC
    CGG
    1203.0
    [m]
    DC
    CGG
    1212.0
    [m]
    DC
    CGG
    1221.0
    [m]
    DC
    CGG
    1230.0
    [m]
    DC
    CGG
    1239.0
    [m]
    DC
    CGG
    1248.0
    [m]
    DC
    CGG
    1269.0
    [m]
    DC
    CGG
    1290.0
    [m]
    DC
    CGG
    1311.0
    [m]
    DC
    CGG
    1332.0
    [m]
    DC
    CGG
    1350.0
    [m]
    DC
    CGG
    1370.0
    [m]
    DC
    CGG
    1391.0
    [m]
    DC
    CGG
    1410.0
    [m]
    DC
    CGG
    1430.0
    [m]
    DC
    CGG
    1450.0
    [m]
    DC
    CGG
    1470.0
    [m]
    DC
    CGG
    1490.0
    [m]
    DC
    CGG
    1510.0
    [m]
    DC
    CGG
    1530.0
    [m]
    DC
    CGG
    1550.0
    [m]
    DC
    CGG
    1570.0
    [m]
    DC
    CGG
    1590.0
    [m]
    DC
    CGG
    1616.0
    [m]
    DC
    CGG
    1630.0
    [m]
    DC
    CGG
    1650.0
    [m]
    DC
    CGG
    1670.0
    [m]
    DC
    CGG
    1690.0
    [m]
    DC
    CGG
    1710.0
    [m]
    DC
    CGG
    1730.0
    [m]
    DC
    CGG
    1750.0
    [m]
    DC
    CGG
    1770.0
    [m]
    DC
    CGG
    1790.0
    [m]
    DC
    CGG
    1810.0
    [m]
    DC
    CGG
    1830.0
    [m]
    DC
    CGG
    1850.0
    [m]
    DC
    CGG
    1870.0
    [m]
    DC
    CGG
    1890.0
    [m]
    DC
    CGG
    1910.0
    [m]
    DC
    CGG
    1930.0
    [m]
    DC
    CGG
    1950.0
    [m]
    DC
    CGG
    1970.0
    [m]
    DC
    CGG
    1976.8
    [m]
    SWC
    CGG
    1990.0
    [m]
    DC
    CGG
    2010.0
    [m]
    DC
    CGG
    2030.0
    [m]
    DC
    CGG
    2050.0
    [m]
    DC
    CGG
    2070.0
    [m]
    DC
    CGG
    2090.0
    [m]
    DC
    CGG
    2110.0
    [m]
    DC
    CGG
    2130.0
    [m]
    DC
    CGG
    2150.0
    [m]
    DC
    CGG
    2170.0
    [m]
    DC
    CGG
    2190.0
    [m]
    DC
    CGG
    2210.0
    [m]
    DC
    CGG
    2230.0
    [m]
    DC
    CGG
    2250.0
    [m]
    DC
    CGG
    2270.0
    [m]
    DC
    CGG
    2286.3
    [m]
    SWC
    CGG
    2290.0
    [m]
    DC
    CGG
    2310.0
    [m]
    DC
    CGG
    2330.0
    [m]
    DC
    CGG
    2350.0
    [m]
    DC
    CGG
    2370.0
    [m]
    DC
    CGG
    2380.0
    [m]
    DC
    CGG
    2390.0
    [m]
    DC
    CGG
    2400.0
    [m]
    DC
    CGG
    2408.0
    [m]
    SWC
    CGG
    2409.0
    [m]
    DC
    CGG
    2418.0
    [m]
    DC
    CGG
    2427.0
    [m]
    DC
    CGG
    2490.0
    [m]
    DC
    CGG
    2511.0
    [m]
    DC
    CGG
    2532.0
    [m]
    DC
    CGG
    2553.0
    [m]
    DC
    CGG
    2572.0
    [m]
    SWC
    CGG
    2574.0
    [m]
    DC
    CGG
    2595.0
    [m]
    DC
    CGG
    2616.0
    [m]
    DC
    CGG
    2637.0
    [m]
    DC
    CGG
    2658.0
    [m]
    DC
    CGG
    2660.0
    [m]
    SWC
    CGG
    2679.0
    [m]
    DC
    CGG
    2700.0
    [m]
    DC
    CGG
    2715.0
    [m]
    SWC
    CGG
    2721.0
    [m]
    DC
    CGG
    2742.0
    [m]
    DC
    CGG
    2763.0
    [m]
    DC
    CGG
    2784.0
    [m]
    DC
    CGG
    2805.0
    [m]
    DC
    CGG
    2812.0
    [m]
    SWC
    CGG
    2826.0
    [m]
    DC
    CGG
    2847.0
    [m]
    DC
    CGG
    2868.0
    [m]
    DC
    CGG
    2889.0
    [m]
    DC
    CGG
    2897.0
    [m]
    SWC
    CGG
    2910.0
    [m]
    DC
    CGG
    2931.0
    [m]
    DC
    CGG
    2952.0
    [m]
    DC
    CGG
    2973.0
    [m]
    DC
    CGG
    2984.0
    [m]
    SWC
    CGG
    2994.0
    [m]
    DC
    CGG
    3015.0
    [m]
    DC
    CGG
    3036.0
    [m]
    DC
    CGG
    3057.0
    [m]
    DC
    CGG
    3078.0
    [m]
    DC
    CGG
    3081.0
    [m]
    SWC
    CGG
    3099.0
    [m]
    DC
    CGG
    3120.0
    [m]
    DC
    CGG
    3141.0
    [m]
    DC
    CGG
    3162.0
    [m]
    DC
    CGG
    3175.0
    [m]
    SWC
    CGG
    3183.0
    [m]
    DC
    CGG
    3201.0
    [m]
    DC
    CGG
    3213.0
    [m]
    DC
    CGG
    3225.0
    [m]
    DC
    CGG
    3237.0
    [m]
    DC
    CGG
    3249.0
    [m]
    DC
    CGG
    3257.0
    [m]
    SWC
    CGG
    3261.0
    [m]
    DC
    CGG
    3273.0
    [m]
    DC
    CGG
    3285.0
    [m]
    DC
    CGG
    3297.0
    [m]
    DC
    CGG
    3309.0
    [m]
    DC
    CGG
    3321.0
    [m]
    DC
    CGG
    3322.5
    [m]
    SWC
    CGG
    3333.0
    [m]
    DC
    CGG
    3345.0
    [m]
    DC
    CGG
    3357.0
    [m]
    DC
    CGG
    3369.0
    [m]
    DC
    CGG
    3373.5
    [m]
    SWC
    CGG
    3381.0
    [m]
    DC
    CGG
    3393.0
    [m]
    DC
    CGG
    3395.2
    [m]
    SWC
    CGG
    3405.0
    [m]
    DC
    CGG
    3415.0
    [m]
    SWC
    CGG
    3420.0
    [m]
    DC
    CGG
    3435.0
    [m]
    DC
    CGG
    3445.0
    [m]
    SWC
    CGG
    3450.0
    [m]
    DC
    CGG
    3459.0
    [m]
    DC
    CGG
    3462.5
    [m]
    SWC
    CGG
    3474.0
    [m]
    DC
    CGG
    3489.0
    [m]
    DC
    CGG
    3491.0
    [m]
    SWC
    CGG
    3504.0
    [m]
    DC
    CGG
    3518.0
    [m]
    SWC
    CGG
    3519.0
    [m]
    DC
    CGG
    3528.0
    [m]
    DC
    CGG