Faktasider Sokkeldirektoratet
Faktasider Sokkeldirektoratet
sodir.no          English
08.05.2024 - 01:33
Tidspunkt for siste synkronisering med Sokkeldirektoratets interne systemer

7335/3-1

Eksport: PDF ikon PDF
  • Generell informasjon

    Generell informasjon
    Attributt Verdi
    Brønnbane navn
    Offisielt navn på brønnbanen ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    7335/3-1
    Type
    Brønnbanetype. Lovlige verdier: EXPLORATION, DEVELOPMENT, OTHER (se 'Formål' for mer informasjon)
    EXPLORATION
    Formål
    Endelig klassifisering av brønnbanen.

    Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Lovlige verdier for utvinningsbrønnbaner:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Lovlig verdier for andre brønnbaner:
    SOIL DRILLING (boring ifm trase og andre grunnundersøkelser som gjøres for å undersøke grunnforholdene i forkant av plassering av innretninger),
    SHALLOW GAS (undersøke grunn gass før første boring på lokasjon),
    PILOT (undersøke geologi og væskekontakter for plassering av hovedbrønnbanen),
    SCIENTIFIC (bores ihhtLov om vitenskapelige undersøkelser),
    STRATIGRAPHIC (bores ihht Petroleumsloven §2-1).
    WILDCAT
    Status
    Status for brønnbanen. Lovlige verdier:

    BLOWOUT: Det har vært blowout i brønnen.
    CLOSED: Utvinningsbrønnbane som er stengt for produksjon/injeksjon i kortere eller lengre periode. Statusen er også brukt på ferdig borete brønnbaner, der månedlig produksjon/injeksjon ikke har blitt rapportert enda.
    DRILLING: Brønnen er i borefasen. Kan være i aktiv boring, logging, testing eller plugging.
    JUNKED: Boringen ble avsluttet pga tekniske problemer,
    P&A: For letebrønnbane: brønnbanen er plugget og forlatt, og kan ikke re-entres for videre bruk. For utvinningsbrønnbane: produksjon/injeksjon er avsluttet og brønnen er plugget. Brønnhodet er fjernet eller på annet vis gjort utilgjengelig for nye brønnoperasjoner.
    PLUGGED: Brønnbane som er plugget, men øvre deler av brønnbanen kan brukes til å bore nye sidesteg mot nye boremål.
    PRODUCING: Det ble produsert fra brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    INJECTING: Det ble injisert i brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    SUSPENDED: Brønnbane der boringen er midlertidig stoppet. Rettighetshaverne planlegger å fortsette boringen på et senere tidspunkt.
    WILL NEVER BE DRILLED: Brønnbane som er registrert med navn og WellID av Sokkeldirektoratet, men som av ulike årsaker ikke vil bli boret.
    P&A
    Pressemelding
    Faktakart i nytt vindu
    Hovedområde
    Navn på området på norsk koninentalsokkel hvor brønnbanen ligger. Lovlige verdier: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    BARENTS SEA
    Brønn navn
    Offisielt navn på brønnen som brønnbanen tilhører ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    7335/3-1
    Seismisk lokalisering
    Brønnbanens lokalisering (ved spud-posisjon) på seismiske linjer. SP: Skuddpunkt.
    ST14005T15 Inline: 4481. Xline: 8373
    Utvinningstillatelse
    Offisielt navn på utvinningstillatelsen som brønnbanen ble boret eller planlegges boret ut fra (brønnhodeposisjonen).
    Boreoperatør
    Navn på rettighetshaver som på vegne av den aktive utvinningstillatelsen (ved brønnhodeposisjon) starter boreoperasjonen. Dette tilsvarer vanligvis operatørselskapet for den aktuelle utvinningstillatelsen.
    Equinor Energy AS
    Boretillatelse
    Boretillatelsesnummer sammen med versjon av boretillatelsen som angitt i boretillatelsen gitt av Sokkeldirektoratet.
    1760-L
    Boreinnretning
    Sokkeldirektoratets navn på innretningen som brønnbanen ble boret fra.
    Boredager
    Antall dager fra borestart til boreslutt.
    34
    Borestart
    Dato borekrona trengte gjennom jordskorpa. For sidesteg: Datoen ny formasjon blir boret, se også utboringsdyp.
    13.05.2019
    Boreslutt
    Letebrønner fra flyttbare innretninger:
    For flytende innretninger - dato når ankerhåndteringen startet.For oppjekkbare innretninger - dato for oppstart av nedjekking.
    Letebrønner fra faste innretninger og alle utvinningsbrønner:
    Dato for når totalt dyp er nådd og siste foringsrør, casing eller screen er satt. Ved umiddelbar plugging av brønnbanen, tilsvarer boreslutt datoen siste plugg er satt.
    15.06.2019
    Plugget og forlatt dato
    Dato P&A-operasjonen av brønnbanen var ferdig, som innmeldt av operatør til DDRS (Daily Drilling Reporting System). Forekommer bare en gang pr. brønnhode/overflateposisjon.
    15.06.2019
    Frigitt dato
    Dato for når rådata som er innrapportert til myndighetene fra brønnen ikke lenger er undergitt taushetsplikt. Normalt ca 2 år etter boreslutt. Kan være tidligere hvis arealet for utvinningstillatelsen er tilbakelevert.
    28.10.2020
    Publiseringsdato
    Dato kvalitetskontroll av informasjon om brønnbanen ble ferdig, slik at den kan publiseres på internett som en 'Well Data Summary Sheet brønnbane', dvs. med mer informasjon tilgjengelig enn for andre brønnbaner.
    30.04.2021
    Opprinnelig formål
    Formålet med brønnbanen definert før borestart.Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Eksempler på lovlige verdier for utvinningsbrønnbaner: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Gjenåpnet
    Status om brønnbanen er gjenåpnet (YES) eller ikke (NO). Når en teller antall brønnbaner på norsk sokkel, teller en bare de som ikke er gjenåpnet (NO).
    NO
    Innhold
    For letebrønnbaner, funn status.

    Lovlige verdier: DRY, SHOWS (spor av hydrokarboner), GAS, GAS/CONDENSATE, OIL eller OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS eller OIL/GAS SHOWS) er oppdaget som fluorescerende kutt (organisk ekstrakt), lukt av petroleum, eller synlig belegg på borekaks eller borekjerner, eller som økte gassavlesninger i slamloggerens detekteringsutstyr.
    Lovlige verdier for WILDCAT-CCS og APPRAISAL-CCS: WATER

    For utvinningsbrønnbaner, type produsert eller injisert fluid.
    Lovlige verdier: WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    DRY
    Funnbrønnbane
    Indikator som forteller om brønnbanen påviste et nytt funn. Lovlige verdier: YES, NO. For brønnbaner der resultatet ikke er pressemeldt eller på annet vis avklart, blir «NO» benyttet.
    NO
    Avstand, boredekk - midlere havflate [m]
    Avstand i meter mellom boredekk og midlere havnivå (RKB).
    31.0
    Vanndybde ved midlere havflate [m]
    Dybde i meter mellom midlere havflate og havbunn.
    239.0
    Totalt målt dybde (MD) [m RKB]
    Målt lengde av brønnbanen fra boredekket til bunnen av brønnbanen ("driller`s depth").
    4300.0
    Totalt vertikalt dybde (TVD) [m RKB]
    Vertikalt dybde fra dypet ved slutten av brønnbanen til boredekket. Vises bare på brønner som er frigitt. Referert til som sant vertikalt dyp (TVD: TrueVerticalDepth).
    4300.0
    Eldste penetrerte alder
    Alder (iflg. Geologic Time Scale 2004 by F. M. Gradstein, et al. (2004)) til den eldste formasjonen det er blitt boret gjennom. Kan avvike fra alder ved TD for eksempel i avviksbrønner. Eksempler for lovlige verdier: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EARLY PERMIAN, EARLY TRIASSIC, EOCENE.
    TRIASSIC
    Eldste penetrerte formasjon
    Navn på den eldste litostratigrafiske enheten som brønnbanen har penetrert. Vises bare på brønner som er frigitt. I de fleste brønnbaner er dette formasjonen eller gruppen påtruffet i bunnen av brønnbanen. Kan avvike fra formasjonen eller gruppen ved TD for eksempel i brønnbaner som er boret med høy avvik eller gjennom forkastninger. Eksempler på lovlige verdier: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, SHETLAND GP.
    HAVERT FM
    Geodetisk datum
    Referansesystem for koordinater. Eksempel på lovlige verdier: ED50.
    ED50
    NS grader
    Geografisk koordinat for brønnhode, nord-sør grader.
    73° 59' 49.86'' N
    ØV grader
    Geografisk koordinat for brønnhode, øst-vest grader.
    35° 50' 13.73'' E
    NS UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, nord-sør.
    8214534.56
    ØV UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, øst-vest.
    402709.14
    UTM sone
    Universal Transverse Mercator sone. Eksempel på lovlige verdier: 31, 32, 33, 34.
    37
    NPDID for brønnbanen
    Sokkeldirektoratets entydige nøkkel for brønnbanen.
    8735
  • Brønnhistorie

    Well 7335/3-1 was drilled to test the Korpfjell Deep on the Haapet Dome far north-east on the Bjarmeland Platform in the Barents Sea. The prospect is a faulted dome, divided into several segments, separated by faults and saddle points. Well 7335/3-1 was the second well drilled on the structure. The primary objective was to test the Realgrunnen Subgroup within the Kapp Toscana Group in segment B, and if oil is discovered, to acquire enough data to determine commerciality and need of appraisal wells. The secondary objectives were to test 4 deeper targets within the central segments: the Intra Snadd Formation Carnian sandstone, the Kobbe Formation, the Havert Formation and Havert clinoforms. The well should also clarify presence of Late Permian source rocks (Ørret Formation), if feasible. The well was committed to drill to 4000 m MSL.
    Operations and results
    A 9 7/8” pilot well (7335/3-U-1) was drilled ca 26 m southeast of the main well to confirm the stratigraphic depth prognosis in order to prevent riserless drilling into reservoir in main well. The pilot was drilled to 547 m, below setting depth for the 20” casing shoe in the main well. No shallow gas or water flow was observed and the prognosed stratigraphy was confirmed.
    Wildcat well 7335/33-1 was spudded with the semi-submersible installation West Hercules on 13 May 2019 and drilled to TD at 4300 m in the Triassic Havert Formation. Operations proceeded without significant problems. The well was drilled with seawater and hi-vis pills down to 537 m, with Glydril mud from 537 to from 1046 m and with Exploradril oil-based mud from 1046 m to TD.
    Water filled reservoir with good reservoir properties was encountered within the Realgrunnen Subgroup. The well encountered sandy but tight intervals within the Havert Formation (primary target) and in the Klappmyss Formation. Tight sands were also encountered within the Kobbe and Snadd formations. The well TD’d above the Permian, so potential source rock within the Ørret Formation was not evaluated.
    No conclusive shows were recorded in the well. Direct fluorescence (no cut) in the interval 980 to 1027 m was observed in carbonaceous claystone in the Snadd Formation. Elevated mud gas was recorded in the same interval. The gas was however dry and believed to be related to the rather extensive coal layers and carbonaceous claystones observed in the ditch cuttings. Other observed fluorescence in the sections that was drilled water-based is interpreted as mineral fluorescence or even due to the glycol additive in the mud. In the oil-based sections no oil shows were observed on cuttings or sidewall cores. Several relative high peaks with very dry gas were however registered in the lower Havert Formation
    No cores were cut. No fluid sample was taken.
    The well was permanently abandoned on 15 June 2019 as a dry well.
    Testing
    No drill stem test was performed.
  • Borekaks i Sokkeldirektoratet

    Borekaks i Sokkeldirektoratet
    Borekaks tilgjengelig for prøvetaking?
    YES
    Borekaks i Sokkeldirektoratet
    Borekaksprøve, topp dybde [m]
    Borekaksprøve, bunn dybde [m]
    540.00
    4300.00
  • Palynologiske preparater i Sokkeldirektoratet

    Palynologiske preparater i Sokkeldirektoratet
    Prøve dybde
    Dybde enhet
    Prøve type
    Laboratorie
    540.0
    [m]
    DC
    CGG
    543.0
    [m]
    DC
    CGG
    549.0
    [m]
    DC
    CGG
    555.0
    [m]
    DC
    CGG
    561.0
    [m]
    DC
    CGG
    567.0
    [m]
    DC
    CGG
    573.0
    [m]
    DC
    CGG
    576.0
    [m]
    DC
    CGG
    579.0
    [m]
    DC
    CGG
    582.0
    [m]
    DC
    CGG
    591.0
    [m]
    DC
    CGG
    600.0
    [m]
    DC
    CGG
    609.0
    [m]
    DC
    CGG
    618.0
    [m]
    DC
    CGG
    627.0
    [m]
    DC
    CGG
    636.0
    [m]
    DC
    CGG
    644.0
    [m]
    DC
    CGG
    654.0
    [m]
    DC
    CGG
    663.0
    [m]
    DC
    CGG
    669.0
    [m]
    DC
    CGG
    678.0
    [m]
    DC
    CGG
    687.0
    [m]
    DC
    CGG
    696.0
    [m]
    DC
    CGG
    705.0
    [m]
    DC
    CGG
    714.0
    [m]
    DC
    CGG
    723.0
    [m]
    DC
    CGG
    732.0
    [m]
    DC
    CGG
    741.0
    [m]
    DC
    CGG
    750.0
    [m]
    DC
    CGG
    759.0
    [m]
    DC
    CGG
    768.0
    [m]
    DC
    CGG
    777.0
    [m]
    DC
    CGG
    786.0
    [m]
    DC
    CGG
    795.0
    [m]
    DC
    CGG
    804.0
    [m]
    DC
    CGG
    813.0
    [m]
    DC
    CGG
    822.0
    [m]
    DC
    CGG
    831.0
    [m]
    DC
    CGG
    840.0
    [m]
    DC
    CGG
    849.0
    [m]
    DC
    CGG
    858.0
    [m]
    DC
    CGG
    867.0
    [m]
    DC
    CGG
    876.0
    [m]
    DC
    CGG
    885.0
    [m]
    DC
    CGG
    894.0
    [m]
    DC
    CGG
    903.0
    [m]
    DC
    CGG
    912.0
    [m]
    DC
    CGG
    921.0
    [m]
    DC
    CGG
    930.0
    [m]
    DC
    CGG
    939.0
    [m]
    DC
    CGG
    948.0
    [m]
    DC
    CGG
    957.0
    [m]
    DC
    CGG
    966.0
    [m]
    DC
    CGG
    975.0
    [m]
    DC
    CGG
    984.0
    [m]
    DC
    CGG
    993.0
    [m]
    DC
    CGG
    1002.0
    [m]
    DC
    CGG
    1011.0
    [m]
    DC
    CGG
    1020.0
    [m]
    DC
    CGG
    1029.0
    [m]
    DC
    CGG
    1038.0
    [m]
    DC
    CGG
    1046.0
    [m]
    DC
    CGG
    1056.0
    [m]
    DC
    CGG
    1065.0
    [m]
    DC
    CGG
    1077.0
    [m]
    DC
    CGG
    1095.0
    [m]
    DC
    CGG
    1113.0
    [m]
    DC
    CGG
    1131.0
    [m]
    DC
    CGG
    1149.0
    [m]
    DC
    CGG
    1158.0
    [m]
    DC
    CGG
    1167.0
    [m]
    DC
    CGG
    1176.0
    [m]
    DC
    CGG
    1185.0
    [m]
    DC
    CGG
    1194.0
    [m]
    DC
    CGG
    1203.0
    [m]
    DC
    CGG
    1212.0
    [m]
    DC
    CGG
    1221.0
    [m]
    DC
    CGG
    1230.0
    [m]
    DC
    CGG
    1239.0
    [m]
    DC
    CGG
    1266.0
    [m]
    DC
    CGG
    1293.0
    [m]
    DC
    CGG
    1320.0
    [m]
    DC
    CGG
    1347.0
    [m]
    DC
    CGG
    1374.0
    [m]
    DC
    CGG
    1401.0
    [m]
    DC
    CGG
    1428.0
    [m]
    DC
    CGG
    1455.0
    [m]
    DC
    CGG
    1482.0
    [m]
    DC
    CGG
    1509.0
    [m]
    DC
    CGG
    1536.0
    [m]
    DC
    CGG
    1563.0
    [m]
    DC
    CGG
    1590.0
    [m]
    DC
    CGG
    1617.0
    [m]
    DC
    CGG
    1644.0
    [m]
    DC
    CGG
    1671.0
    [m]
    DC
    CGG
    1698.0
    [m]
    DC
    CGG
    1725.0
    [m]
    DC
    CGG
    1752.0
    [m]
    DC
    CGG
    1779.0
    [m]
    DC
    CGG
    1806.0
    [m]
    DC
    CGG
    1833.0
    [m]
    DC
    CGG
    1860.0
    [m]
    DC
    CGG
    1887.0
    [m]
    DC
    CGG
    1914.0
    [m]
    DC
    CGG
    1941.0
    [m]
    DC
    CGG
    1968.0
    [m]
    DC
    CGG
    1995.0
    [m]
    DC
    CGG
    2022.0
    [m]
    DC
    CGG
    2049.0
    [m]
    DC
    CGG
    2076.0
    [m]
    DC
    CGG
    2103.0
    [m]
    DC
    CGG
    2130.0
    [m]
    DC
    CGG
    2157.0
    [m]
    DC
    CGG
    2184.0
    [m]
    DC
    CGG
    2211.0
    [m]
    DC
    CGG
    2238.0
    [m]
    DC
    CGG
    2265.0
    [m]
    DC
    CGG
    2631.4
    [m]
    SWC
    CGG
    2790.0
    [m]
    DC
    CGG
    2826.0
    [m]
    DC
    CGG
    2871.0
    [m]
    DC
    CGG
    2898.0
    [m]
    DC
    CGG
    2925.0
    [m]
    DC
    CGG
    2952.0
    [m]
    DC
    CGG
    2969.0
    [m]
    SWC
    CGG
    2991.0
    [m]
    DC
    CGG
    3018.0
    [m]
    DC
    CGG
    3045.0
    [m]
    DC
    CGG
    3072.0
    [m]
    DC
    CGG
    3099.0
    [m]
    DC
    CGG
    3126.0
    [m]
    DC
    CGG
    3153.0
    [m]
    DC
    CGG
    3180.0
    [m]
    DC
    CGG
    3195.0
    [m]
    SWC
    CGG
    3222.0
    [m]
    DC
    CGG
    3249.0
    [m]
    DC
    CGG
    3276.0
    [m]
    DC
    CGG
    3303.0
    [m]
    DC
    CGG
    3330.0
    [m]
    DC
    CGG
    3357.0
    [m]
    DC
    CGG
    3381.0
    [m]
    DC
    CGG
    3408.0
    [m]
    DC
    CGG
    3431.0
    [m]
    SWC
    CGG
    3444.0
    [m]
    DC
    CGG
    3471.0
    [m]
    DC
    CGG
    3498.0
    [m]
    DC
    CGG
    3525.0
    [m]
    DC
    CGG
    3552.0
    [m]
    DC
    CGG
    3579.0
    [m]
    DC
    CGG
    3606.0
    [m]
    DC
    CGG
    3633.0
    [m]
    DC
    CGG
    3650.0
    [m]
    SWC
    CGG
    3669.0
    [m]
    DC
    CGG
    3696.0
    [m]
    DC
    CGG
    3723.0
    [m]
    DC
    CGG
    3744.0
    [m]
    SWC
    CGG
    3768.0
    [m]
    DC
    CGG
    3795.0
    [m]
    DC
    CGG
    3822.0
    [m]
    DC
    CGG
    3848.0
    [m]
    SWC
    CGG
    3858.0
    [m]
    SWC
    CGG
    3869.4
    [m]
    SWC
    CGG
    3880.0
    [m]
    SWC
    CGG
    3903.0
    [m]
    DC
    CGG
    3930.0
    [m]
    DC
    CGG
    3957.0
    [m]
    DC
    CGG
    3979.0
    [m]
    SWC
    CGG
    4000.0
    [m]
    SWC
    CGG
    4017.0
    [m]
    DC
    CGG
    4044.0
    [m]
    DC
    CGG
    4062.5
    [m]
    SWC
    CGG
    4071.3
    [m]
    SWC
    CGG
    4087.5
    [m]
    SWC
    CGG
    4112.5
    [m]
    SWC
    CGG
    4130.0
    [m]
    DC
    CGG
    4145.0
    [m]
    SWC
    CGG
    4173.0
    [m]
    DC
    CGG
    4199.0
    [m]
    SWC
    CGG
    4224.0
    [m]
    DC
    CGG
    4251.0
    [m]
    DC
    CGG
    4270.2
    [m]
    SWC
    CGG
    4284.0
    [m]
    DC
    CGG
    4300.0
    [m]
    DC
    CGG
  • Litostratigrafi

  • Logger

    Logger
    Type logg
    Topp dyp for logg [m]
    Bunn dyp for logg [m]
    MWD - ARC TELE
    322
    644
    MWD - PD ARC TELE
    644
    1046
    MWD - PD GVR ARC TELE SS ADN WDP
    1046
    2601
    MWD - PD GVR ES TS SS WDP
    2601
    4300
    MWD - TELE
    270
    322
    XLR
    2631
    4270
    ZO VSP
    256
    4279
  • Foringsrør og formasjonsstyrketester

    Foringsrør og formasjonsstyrketester
    Type utforing
    Utforing diam.
    [tommer]
    Utforing dybde
    [m]
    Brønnbane diam.
    [tommer]
    Brønnbane dyp
    [m]
    LOT/FIT slam eqv.
    [g/cm3]
    Type formasjonstest
    CONDUCTOR
    36
    318.4
    42
    322.6
    0.00
    SURF.COND.
    20
    531.2
    26
    537.0
    1.64
    FIT
    PILOT HOLE
    644.0
    12 1/4
    644.0
    0.00
    INTERM.
    13 5/8
    1040.6
    16
    1046.0
    2.06
    LOT
    INTERM.
    9 5/8
    2600.0
    12 1/4
    2601.0
    1.77
    LOT
    OPEN HOLE
    4300.0
    8 1/2
    4300.0
    0.00
  • Boreslam

    Boreslam
    Dybde MD [m]
    Egenvekt, slam [g/cm3]
    Viskositet, slam [mPa.s]
    Flytegrense [Pa]
    Type slam
    Dato, måling
    492
    1.18
    17.5
    Glydril
    492
    1.18
    17.5
    Seawater
    590
    1.14
    14.0
    Glydril
    1041
    1.14
    17.0
    Glydril
    1049
    1.14
    15.0
    EMS 4400
    2380
    1.14
    16.0
    EMS 4400
    2703
    1.14
    17.0
    EMS 4400
    3862
    1.16
    16.0
    EMS 4400
    4035
    1.17
    17.5
    EMS 4400
    4300
    1.18
    17.5
    EMS 4400