Faktasider Sokkeldirektoratet
Faktasider Sokkeldirektoratet
sodir.no          English
08.05.2024 - 01:33
Tidspunkt for siste synkronisering med Sokkeldirektoratets interne systemer

11/10-1

Eksport: PDF ikon PDF
  • Generell informasjon

    Generell informasjon
    Attributt Verdi
    Brønnbane navn
    Offisielt navn på brønnbanen ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    11/10-1
    Type
    Brønnbanetype. Lovlige verdier: EXPLORATION, DEVELOPMENT, OTHER (se 'Formål' for mer informasjon)
    EXPLORATION
    Formål
    Endelig klassifisering av brønnbanen.

    Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Lovlige verdier for utvinningsbrønnbaner:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Lovlig verdier for andre brønnbaner:
    SOIL DRILLING (boring ifm trase og andre grunnundersøkelser som gjøres for å undersøke grunnforholdene i forkant av plassering av innretninger),
    SHALLOW GAS (undersøke grunn gass før første boring på lokasjon),
    PILOT (undersøke geologi og væskekontakter for plassering av hovedbrønnbanen),
    SCIENTIFIC (bores ihhtLov om vitenskapelige undersøkelser),
    STRATIGRAPHIC (bores ihht Petroleumsloven §2-1).
    WILDCAT
    Status
    Status for brønnbanen. Lovlige verdier:

    BLOWOUT: Det har vært blowout i brønnen.
    CLOSED: Utvinningsbrønnbane som er stengt for produksjon/injeksjon i kortere eller lengre periode. Statusen er også brukt på ferdig borete brønnbaner, der månedlig produksjon/injeksjon ikke har blitt rapportert enda.
    DRILLING: Brønnen er i borefasen. Kan være i aktiv boring, logging, testing eller plugging.
    JUNKED: Boringen ble avsluttet pga tekniske problemer,
    P&A: For letebrønnbane: brønnbanen er plugget og forlatt, og kan ikke re-entres for videre bruk. For utvinningsbrønnbane: produksjon/injeksjon er avsluttet og brønnen er plugget. Brønnhodet er fjernet eller på annet vis gjort utilgjengelig for nye brønnoperasjoner.
    PLUGGED: Brønnbane som er plugget, men øvre deler av brønnbanen kan brukes til å bore nye sidesteg mot nye boremål.
    PRODUCING: Det ble produsert fra brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    INJECTING: Det ble injisert i brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    SUSPENDED: Brønnbane der boringen er midlertidig stoppet. Rettighetshaverne planlegger å fortsette boringen på et senere tidspunkt.
    WILL NEVER BE DRILLED: Brønnbane som er registrert med navn og WellID av Sokkeldirektoratet, men som av ulike årsaker ikke vil bli boret.
    P&A
    Faktakart i nytt vindu
    Hovedområde
    Navn på området på norsk koninentalsokkel hvor brønnbanen ligger. Lovlige verdier: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    NORTH SEA
    Brønn navn
    Offisielt navn på brønnen som brønnbanen tilhører ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    11/10-1
    Seismisk lokalisering
    Brønnbanens lokalisering (ved spud-posisjon) på seismiske linjer. SP: Skuddpunkt.
    LINE 610 SP. 2050.
    Utvinningstillatelse
    Offisielt navn på utvinningstillatelsen som brønnbanen ble boret eller planlegges boret ut fra (brønnhodeposisjonen).
    Boreoperatør
    Navn på rettighetshaver som på vegne av den aktive utvinningstillatelsen (ved brønnhodeposisjon) starter boreoperasjonen. Dette tilsvarer vanligvis operatørselskapet for den aktuelle utvinningstillatelsen.
    Syracuse Oils Norge A/S
    Boretillatelse
    Boretillatelsesnummer sammen med versjon av boretillatelsen som angitt i boretillatelsen gitt av Sokkeldirektoratet.
    31-L
    Boreinnretning
    Sokkeldirektoratets navn på innretningen som brønnbanen ble boret fra.
    Boredager
    Antall dager fra borestart til boreslutt.
    18
    Borestart
    Dato borekrona trengte gjennom jordskorpa. For sidesteg: Datoen ny formasjon blir boret, se også utboringsdyp.
    02.08.1969
    Boreslutt
    Letebrønner fra flyttbare innretninger:
    For flytende innretninger - dato når ankerhåndteringen startet.For oppjekkbare innretninger - dato for oppstart av nedjekking.
    Letebrønner fra faste innretninger og alle utvinningsbrønner:
    Dato for når totalt dyp er nådd og siste foringsrør, casing eller screen er satt. Ved umiddelbar plugging av brønnbanen, tilsvarer boreslutt datoen siste plugg er satt.
    19.08.1969
    Frigitt dato
    Dato for når rådata som er innrapportert til myndighetene fra brønnen ikke lenger er undergitt taushetsplikt. Normalt ca 2 år etter boreslutt. Kan være tidligere hvis arealet for utvinningstillatelsen er tilbakelevert.
    19.08.1971
    Publiseringsdato
    Dato kvalitetskontroll av informasjon om brønnbanen ble ferdig, slik at den kan publiseres på internett som en 'Well Data Summary Sheet brønnbane', dvs. med mer informasjon tilgjengelig enn for andre brønnbaner.
    01.12.2004
    Opprinnelig formål
    Formålet med brønnbanen definert før borestart.Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Eksempler på lovlige verdier for utvinningsbrønnbaner: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Gjenåpnet
    Status om brønnbanen er gjenåpnet (YES) eller ikke (NO). Når en teller antall brønnbaner på norsk sokkel, teller en bare de som ikke er gjenåpnet (NO).
    NO
    Innhold
    For letebrønnbaner, funn status.

    Lovlige verdier: DRY, SHOWS (spor av hydrokarboner), GAS, GAS/CONDENSATE, OIL eller OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS eller OIL/GAS SHOWS) er oppdaget som fluorescerende kutt (organisk ekstrakt), lukt av petroleum, eller synlig belegg på borekaks eller borekjerner, eller som økte gassavlesninger i slamloggerens detekteringsutstyr.
    Lovlige verdier for WILDCAT-CCS og APPRAISAL-CCS: WATER

    For utvinningsbrønnbaner, type produsert eller injisert fluid.
    Lovlige verdier: WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    DRY
    Funnbrønnbane
    Indikator som forteller om brønnbanen påviste et nytt funn. Lovlige verdier: YES, NO. For brønnbaner der resultatet ikke er pressemeldt eller på annet vis avklart, blir «NO» benyttet.
    NO
    Avstand, boredekk - midlere havflate [m]
    Avstand i meter mellom boredekk og midlere havnivå (RKB).
    27.0
    Vanndybde ved midlere havflate [m]
    Dybde i meter mellom midlere havflate og havbunn.
    58.0
    Totalt målt dybde (MD) [m RKB]
    Målt lengde av brønnbanen fra boredekket til bunnen av brønnbanen ("driller`s depth").
    2430.0
    Totalt vertikalt dybde (TVD) [m RKB]
    Vertikalt dybde fra dypet ved slutten av brønnbanen til boredekket. Vises bare på brønner som er frigitt. Referert til som sant vertikalt dyp (TVD: TrueVerticalDepth).
    2430.0
    Temperatur ved bunn av brønnbanen [°C]
    Estimert temperatur ved bunnen av brønnbanen. Vises bare på brønner som er frigitt. Se beskrivelse.
    68
    Eldste penetrerte alder
    Alder (iflg. Geologic Time Scale 2004 by F. M. Gradstein, et al. (2004)) til den eldste formasjonen det er blitt boret gjennom. Kan avvike fra alder ved TD for eksempel i avviksbrønner. Eksempler for lovlige verdier: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EARLY PERMIAN, EARLY TRIASSIC, EOCENE.
    TRIASSIC
    Eldste penetrerte formasjon
    Navn på den eldste litostratigrafiske enheten som brønnbanen har penetrert. Vises bare på brønner som er frigitt. I de fleste brønnbaner er dette formasjonen eller gruppen påtruffet i bunnen av brønnbanen. Kan avvike fra formasjonen eller gruppen ved TD for eksempel i brønnbaner som er boret med høy avvik eller gjennom forkastninger. Eksempler på lovlige verdier: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, SHETLAND GP.
    SKAGERRAK FM
    Geodetisk datum
    Referansesystem for koordinater. Eksempel på lovlige verdier: ED50.
    ED50
    NS grader
    Geografisk koordinat for brønnhode, nord-sør grader.
    57° 0' 46'' N
    ØV grader
    Geografisk koordinat for brønnhode, øst-vest grader.
    6° 10' 4.7'' E
    NS UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, nord-sør.
    6322515.78
    ØV UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, øst-vest.
    328039.30
    UTM sone
    Universal Transverse Mercator sone. Eksempel på lovlige verdier: 31, 32, 33, 34.
    32
    NPDID for brønnbanen
    Sokkeldirektoratets entydige nøkkel for brønnbanen.
    170
  • Brønnhistorie

    General
    Wildcat well 11/10-1 was drilled in the eastern part of the Danish Norwegian Basin close to the borderline between the Norwegian and the Danish sectors. The well is situated close to the Kreps fault zone on the western flank of the Horns Graben. The main objectives of the 11/10-1 well were to test the hydrocarbon potential of the Tertiary and the Mesozoic formations. Well 11/10-1 is the first well in quadrant 11 and one of the few wells drilled in the southeastern part of the Norwegian continental shelf so long.
    Operations and results
    Wildcat well 11/10-1 was spudded with the semi-submersible rig "Ocean Viking" on 2 August 1969 and completed 19 August the same year. The well was drilled at 63 m water depth and bottomed at a total depth of 2430 m in a Triassic sand section without having encountered hydrocarbons in any of the targets.
    Three casing strings were set in the well. Sea water was used for the initial drilling down to 253 m. From this depth down to 1023 m a sea water gel mud was used and from 1023 down to TD a sea water Q-Broxin mud system was the drilling fluid. No significant drilling problems occurred during the drilling of this well.
    No samples are available from the sea floor down to 305 m. From 305 to 430 m the sampled sequence consists of medium to coarse grained, subangular to subrounded, glauconitic sand and sandstone with scattered rock fragments. The sand is generally unconsolidated and mostly clear quartz and is relatively well sorted. Carbonaceous material, plant remains and shell fragments occur throughout. Dolomitic limestone are also present, increasing towards the bottom of the unit where the dolomite forms the cement of the sand. The underlying shales are dated Late Oligocene, the age of the sandy section is questionable as the upper 300m of the well has not been sampled.
    No sandstones are developed in the Rogaland Group which is much reduced in this well. The Upper Cretaceous chalk formations penetrated below 1048 m are approximately 400 m thick. 200 m of marls and shales containing limestone stringers constitute the Cromer Knoll Group below 1493m. The Upper Jurassic section is 200 m thick and consists of mainly shale with only stringers of sandstone. The Lower and Middle Jurassic section is missing in this well. The interval from 1860 to 1900 is considered to belong to the Triassic Gassum formation. At the top of this sequence there is a bed of light grey lime mudstone. Most of the interval, however, consists of loose, clear quartz sand, coarse to very coarse and a fine grained white to light grey sandstone with calcareous cement. From 1900 to 2430 m (TD) interbedded reddish and brownish sandstones and shales of the Skagerrak Formation are present. Visual porosity is good throughout this unit. No shows were observed when drilling through almost 600 m of Triassic section.
    Neither fluid samples nor pressure point were taken in this well.
    No cores were taken in this well.
    Test ing
    No drill stem test was performed.
  • Borekaks i Sokkeldirektoratet

    Borekaks i Sokkeldirektoratet
    Borekaks tilgjengelig for prøvetaking?
    NO
    Borekaks i Sokkeldirektoratet
    Borekaksprøve, topp dybde [m]
    Borekaksprøve, bunn dybde [m]
    304.80
    2429.87
  • Palynologiske preparater i Sokkeldirektoratet

    Palynologiske preparater i Sokkeldirektoratet
    Prøve dybde
    Dybde enhet
    Prøve type
    Laboratorie
    1200.0
    [ft]
    DC
    OD
    1300.0
    [ft]
    DC
    OD
    1300.0
    [ft]
    DC
    OD
    1350.0
    [ft]
    DC
    OD
    1400.0
    [ft]
    DC
    OD
    1500.0
    [ft]
    DC
    OD
    1550.0
    [ft]
    DC
    OD
    1550.0
    [ft]
    DC
    OD
    1600.0
    [ft]
    DC
    OD
    1650.0
    [ft]
    DC
    OD
    1700.0
    [ft]
    DC
    OD
    1750.0
    [ft]
    DC
    OD
    1800.0
    [ft]
    DC
    OD
    1850.0
    [ft]
    DC
    OD
    1900.0
    [ft]
    DC
    OD
    2000.0
    [ft]
    DC
    OD
    2050.0
    [ft]
    DC
    OD
    2050.0
    [ft]
    DC
    OD
    2100.0
    [ft]
    DC
    OD
    2200.0
    [ft]
    DC
    OD
    2300.0
    [ft]
    DC
    OD
    2400.0
    [ft]
    DC
    OD
    2500.0
    [ft]
    DC
    OD
    2600.0
    [ft]
    DC
    OD
    2600.0
    [ft]
    DC
    OD
    2700.0
    [ft]
    DC
    OD
    2800.0
    [ft]
    DC
    OD
    2900.0
    [ft]
    DC
    OD
    3000.0
    [ft]
    DC
    OD
    3100.0
    [ft]
    DC
    OD
    3200.0
    [ft]
    DC
    OD
    4840.0
    [ft]
    DC
    OD
    5000.0
    [ft]
    DC
    OD
    5180.0
    [ft]
    DC
    OD
    5360.0
    [ft]
    DC
    OD
    5540.0
    [ft]
    DC
    GEUS
    5600.0
    [ft]
    DC
    GEUS
    5620.0
    [ft]
    DC
    GEUS
    5620.0
    [ft]
    DC
    OD
    5660.0
    [ft]
    DC
    GEUS
    5700.0
    [ft]
    DC
    GEUS
    5760.0
    [ft]
    DC
    GEUS
    5780.0
    [ft]
    DC
    GEUS
    5820.0
    [ft]
    DC
    GEUS
    5860.0
    [ft]
    DC
    GEUS
    5860.0
    [ft]
    DC
    OD
    5920.0
    [ft]
    DC
    GEUS
    5940.0
    [ft]
    DC
    GEUS
    5980.0
    [ft]
    DC
    GEUS
    6000.0
    [ft]
    DC
    GEUS
    6030.0
    [ft]
    DC
    GEUS
    6030.0
    [ft]
    DC
    OD
    6050.0
    [ft]
    DC
    GEUS
    6090.0
    [ft]
    DC
    GEUS
    6120.0
    [ft]
    DC
    GEUS
    6140.0
    [ft]
    DC
    GEUS
    6180.0
    [ft]
    DC
    GEUS
    6210.0
    [ft]
    DC
    GEUS
    6230.0
    [ft]
    DC
    GEUS
    6230.0
    [ft]
    DC
    OD
    6270.0
    [ft]
    DC
    GEUS
    6300.0
    [ft]
    DC
    GEUS
    6330.0
    [ft]
    DC
    GEUS
    6330.0
    [ft]
    DC
    OD
    6360.0
    [ft]
    DC
    GEUS
    6400.0
    [ft]
    DC
    GEUS
    6420.0
    [ft]
    DC
    GEUS
    6420.0
    [ft]
    DC
    GEUS
    6460.0
    [ft]
    DC
    GEUS
    6480.0
    [ft]
    DC
    OD
    6500.0
    [ft]
    DC
    GEUS
    6580.0
    [ft]
    DC
    GEUS
  • Litostratigrafi

  • Spleisede logger

    Spleisede logger
    Dokument navn
    Dokument format
    Dokument størrelse [KB]
    pdf
    0.23
  • Dokumenter – eldre Sokkeldirektoratets WDSS rapporter og andre relaterte dokumenter

    Dokumenter – eldre Sokkeldirektoratets WDSS rapporter og andre relaterte dokumenter
    Dokument navn
    Dokument format
    Dokument størrelse [KB]
    pdf
    0.18
  • Dokumenter – rapportert av utvinningstillatelsen (frigitt ihht til regelverk)

    Dokumenter – rapportert av utvinningstillatelsen (frigitt ihht til regelverk)
    Dokument navn
    Dokument format
    Dokument størrelse [KB]
    pdf
    1.48
    pdf
    0.89
  • Dokumenter – Sokkeldirektoratets publikasjoner

    Dokumenter – Sokkeldirektoratets publikasjoner
    Dokument navn
    Dokument format
    Dokument størrelse [KB]
    pdf
    10.68
    pdf
    38.09
  • Logger

    Logger
    Type logg
    Topp dyp for logg [m]
    Bunn dyp for logg [m]
    GR CAL SONIC
    85
    2426
    IEL
    254
    2429
    VELOCITY
    85
    2430
  • Foringsrør og formasjonsstyrketester

    Foringsrør og formasjonsstyrketester
    Type utforing
    Utforing diam.
    [tommer]
    Utforing dybde
    [m]
    Brønnbane diam.
    [tommer]
    Brønnbane dyp
    [m]
    LOT/FIT slam eqv.
    [g/cm3]
    Type formasjonstest
    SURF.COND.
    20
    130.0
    26
    131.0
    0.00
    LOT
    INTERM.
    13 3/8
    253.0
    17 1/2
    255.0
    0.00
    LOT
    INTERM.
    9 5/8
    1023.0
    12 1/4
    1025.0
    0.00
    LOT
    OPEN HOLE
    2430.0
    8 1/2
    2430.0
    0.00
    LOT
  • Boreslam

    Boreslam
    Dybde MD [m]
    Egenvekt, slam [g/cm3]
    Viskositet, slam [mPa.s]
    Flytegrense [Pa]
    Type slam
    Dato, måling
    253
    1.05
    water based
    1039
    1.13
    40.0
    15.0
    water based
    1463
    1.23
    40.0
    6.0
    water based
    1889
    1.26
    43.0
    8.0
    water based
    2429
    1.26
    40.0
    5.0
    water based