Faktasider Sokkeldirektoratet
Faktasider Sokkeldirektoratet
sodir.no          English
22.11.2024 - 09:09
Tidspunkt for siste synkronisering med Sokkeldirektoratets interne systemer

36/1-3

Eksport: PDF ikon PDF
  • Generell informasjon

    Generell informasjon
    Attributt Verdi
    Brønnbane navn
    Offisielt navn på brønnbanen ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    36/1-3
    Type
    Brønnbanetype. Lovlige verdier: EXPLORATION, DEVELOPMENT, OTHER (se 'Formål' for mer informasjon)
    EXPLORATION
    Formål
    Endelig klassifisering av brønnbanen.

    Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Lovlige verdier for utvinningsbrønnbaner:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Lovlig verdier for andre brønnbaner:
    SOIL DRILLING (boring ifm trase og andre grunnundersøkelser som gjøres for å undersøke grunnforholdene i forkant av plassering av innretninger),
    SHALLOW GAS (undersøke grunn gass før første boring på lokasjon),
    PILOT (undersøke geologi og væskekontakter for plassering av hovedbrønnbanen),
    SCIENTIFIC (bores ihhtLov om vitenskapelige undersøkelser),
    STRATIGRAPHIC (bores ihht Petroleumsloven §2-1).
    WILDCAT
    Status
    Status for brønnbanen. Lovlige verdier:

    BLOWOUT: Det har vært blowout i brønnen.
    CLOSED: Utvinningsbrønnbane som er stengt for produksjon/injeksjon i kortere eller lengre periode. Statusen er også brukt på ferdig borete brønnbaner, der månedlig produksjon/injeksjon ikke har blitt rapportert enda.
    DRILLING: Brønnen er i borefasen. Kan være i aktiv boring, logging, testing eller plugging.
    JUNKED: Boringen ble avsluttet pga tekniske problemer,
    P&A: For letebrønnbane: brønnbanen er plugget og forlatt, og kan ikke re-entres for videre bruk. For utvinningsbrønnbane: produksjon/injeksjon er avsluttet og brønnen er plugget. Brønnhodet er fjernet eller på annet vis gjort utilgjengelig for nye brønnoperasjoner.
    PLUGGED: Brønnbane som er plugget, men øvre deler av brønnbanen kan brukes til å bore nye sidesteg mot nye boremål.
    PRODUCING: Det ble produsert fra brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    INJECTING: Det ble injisert i brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    SUSPENDED: Brønnbane der boringen er midlertidig stoppet. Rettighetshaverne planlegger å fortsette boringen på et senere tidspunkt.
    WILL NEVER BE DRILLED: Brønnbane som er registrert med navn og WellID av Sokkeldirektoratet, men som av ulike årsaker ikke vil bli boret.
    P&A
    Pressemelding
    Flergrensbønn
    Indikator som forteller om brønnbanen er en flergrensbrønn, dvs. har mer enn en gren. Eksempel på lovlige verdier: YES, NO. Se også Sokkeldirektoratets retninglinjer for betegnelse på brønner og brønnbaner.
    NO
    Faktakart i nytt vindu
    Hovedområde
    Navn på området på norsk koninentalsokkel hvor brønnbanen ligger. Lovlige verdier: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    NORTH SEA
    Brønn navn
    Offisielt navn på brønnen som brønnbanen tilhører ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    36/1-3
    Utvinningstillatelse
    Offisielt navn på utvinningstillatelsen som brønnbanen ble boret eller planlegges boret ut fra (brønnhodeposisjonen).
    Boreoperatør
    Navn på rettighetshaver som på vegne av den aktive utvinningstillatelsen (ved brønnhodeposisjon) starter boreoperasjonen. Dette tilsvarer vanligvis operatørselskapet for den aktuelle utvinningstillatelsen.
    Equinor Energy AS
    Boretillatelse
    Boretillatelsesnummer sammen med versjon av boretillatelsen som angitt i boretillatelsen gitt av Sokkeldirektoratet.
    1741-L
    Boreinnretning
    Sokkeldirektoratets navn på innretningen som brønnbanen ble boret fra.
    Boredager
    Antall dager fra borestart til boreslutt.
    25
    Borestart
    Dato borekrona trengte gjennom jordskorpa. For sidesteg: Datoen ny formasjon blir boret, se også utboringsdyp.
    01.03.2019
    Boreslutt
    Letebrønner fra flyttbare innretninger:
    For flytende innretninger - dato når ankerhåndteringen startet.For oppjekkbare innretninger - dato for oppstart av nedjekking.
    Letebrønner fra faste innretninger og alle utvinningsbrønner:
    Dato for når totalt dyp er nådd og siste foringsrør, casing eller screen er satt. Ved umiddelbar plugging av brønnbanen, tilsvarer boreslutt datoen siste plugg er satt.
    25.03.2019
    Frigitt dato
    Dato for når rådata som er innrapportert til myndighetene fra brønnen ikke lenger er undergitt taushetsplikt. Normalt ca 2 år etter boreslutt. Kan være tidligere hvis arealet for utvinningstillatelsen er tilbakelevert.
    25.03.2021
    Plugget og forlatt dato
    Dato P&A-operasjonen av brønnbanen var ferdig, som innmeldt av operatør til DDRS (Daily Drilling Reporting System). Forekommer bare en gang pr. brønnhode/overflateposisjon.
    25.03.2019
    Publiseringsdato
    Dato kvalitetskontroll av informasjon om brønnbanen ble ferdig, slik at den kan publiseres på internett som en 'Well Data Summary Sheet brønnbane', dvs. med mer informasjon tilgjengelig enn for andre brønnbaner.
    30.04.2021
    Opprinnelig formål
    Formålet med brønnbanen definert før borestart.Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Eksempler på lovlige verdier for utvinningsbrønnbaner: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Innhold
    For letebrønnbaner, funn status.

    Lovlige verdier: DRY, SHOWS (spor av hydrokarboner), GAS, GAS/CONDENSATE, OIL eller OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS eller OIL/GAS SHOWS) er oppdaget som fluorescerende kutt (organisk ekstrakt), lukt av petroleum, eller synlig belegg på borekaks eller borekjerner, eller som økte gassavlesninger i slamloggerens detekteringsutstyr.
    Lovlige verdier for WILDCAT-CCS og APPRAISAL-CCS: WATER

    For utvinningsbrønnbaner, type produsert eller injisert fluid.
    Lovlige verdier: WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    DRY
    Funnbrønnbane
    Indikator som forteller om brønnbanen påviste et nytt funn. Lovlige verdier: YES, NO. For brønnbaner der resultatet ikke er pressemeldt eller på annet vis avklart, blir «NO» benyttet.
    NO
    Avstand, boredekk - midlere havflate [m]
    Avstand i meter mellom boredekk og midlere havnivå (RKB).
    40.0
    Vanndybde ved midlere havflate [m]
    Dybde i meter mellom midlere havflate og havbunn.
    230.0
    Totalt målt dybde (MD) [m RKB]
    Målt lengde av brønnbanen fra boredekket til bunnen av brønnbanen ("driller`s depth").
    2913.0
    Totalt vertikalt dybde (TVD) [m RKB]
    Vertikalt dybde fra dypet ved slutten av brønnbanen til boredekket. Vises bare på brønner som er frigitt. Referert til som sant vertikalt dyp (TVD: TrueVerticalDepth).
    2913.0
    Eldste penetrerte formasjon
    Navn på den eldste litostratigrafiske enheten som brønnbanen har penetrert. Vises bare på brønner som er frigitt. I de fleste brønnbaner er dette formasjonen eller gruppen påtruffet i bunnen av brønnbanen. Kan avvike fra formasjonen eller gruppen ved TD for eksempel i brønnbaner som er boret med høy avvik eller gjennom forkastninger. Eksempler på lovlige verdier: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, SHETLAND GP.
    BASEMENT
    Geodetisk datum
    Referansesystem for koordinater. Eksempel på lovlige verdier: ED50.
    ED50
    NS grader
    Geografisk koordinat for brønnhode, nord-sør grader.
    61° 48' 13.85'' N
    ØV grader
    Geografisk koordinat for brønnhode, øst-vest grader.
    4° 6' 53.47'' E
    NS UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, nord-sør.
    6852997.02
    ØV UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, øst-vest.
    558768.94
    UTM sone
    Universal Transverse Mercator sone. Eksempel på lovlige verdier: 31, 32, 33, 34.
    31
    NPDID for brønnbanen
    Sokkeldirektoratets entydige nøkkel for brønnbanen.
    8631
  • Brønnhistorie

    General
    Well 36/1-3 was drilled to test the Presto prospect east-southeast of the Agat Field on the Måløy slope in the North Sea. The primary objective was to test the hydrocarbon potential in the Early Cretaceous upper and lower Agat Formation sandstones.
    Operations and results
    Wildcat well 36/1-3 was spudded with the semi-submersible installation Transocean Spitsbergen on 1 March 2019 and drilled to TD at 2913 m in basement rock. Operations proceeded without significant problems. The well was drilled with seawater and hi-vis pills down to 550 m, with KCl/polymer/GEM mud from 550 m to 1109 m and XP-07 oil-based mud from 1109 m to TD.
    The well penetrated sediments of Nordland, Rogaland, Shetland and Cromer Knoll Groups. The entire succession of the Hordaland Group is eroded in the well location. The Early Cretaceous Åsgard Formation rest directly on basement.
    Top Agat Formation was encountered at 2564 m and was 202 m thick, of which 55 metres is reservoir rocks with good to very good reservoir quality. The well is dry without shows. Sixteen pressure measurement were performed within Agat sandstones with wireline tool and confirmed a water gradient with normal hydrostatic pressure.
    No cores were cut. No fluid sample was taken.
    The well was permanently abandoned on 25 March 2019 as a dry well.
    Testing
    No drill stem test was performed.
  • Borekaks i Sokkeldirektoratet

    Borekaks i Sokkeldirektoratet
    Borekaks tilgjengelig for prøvetaking?
    YES
    Borekaks i Sokkeldirektoratet
    Borekaksprøve, topp dybde [m]
    Borekaksprøve, bunn dybde [m]
    600.00
    2912.00
  • Foringsrør og formasjonsstyrketester

    Foringsrør og formasjonsstyrketester
    Type utforing
    Utforing diam.
    [tommer]
    Utforing dybde
    [m]
    Brønnbane diam.
    [tommer]
    Brønnbane dyp
    [m]
    LOT/FIT slam eqv.
    [g/cm3]
    Type formasjonstest
    CONDUCTOR
    36
    332.0
    42
    336.0
    0.00
    INTERM.
    13 3/8
    1101.0
    17 1/2
    1109.0
    1.52
    LOT
    LINER
    9 5/8
    2489.0
    12 1/4
    2490.0
    1.57
    LOT
    OPEN HOLE
    2913.0
    8 1/2
    2913.0
    0.00
  • Logger

    Logger
    Type logg
    Topp dyp for logg [m]
    Bunn dyp for logg [m]
    MWD - GR RES ECD DIR
    336
    1109
    MWD - GR RES ECD DIR
    2490
    2913
    MWD - GR RES ECD DIR NEU DEN SON
    1109
    2490
    PEX AIT HNGS MSIP XPT
    2437
    2913
    VSI GR
    238
    2913
  • Litostratigrafi

  • Boreslam

    Boreslam
    Dybde MD [m]
    Egenvekt, slam [g/cm3]
    Viskositet, slam [mPa.s]
    Flytegrense [Pa]
    Type slam
    Dato, måling
    336
    1.35
    20.0
    KCl/Polymer/GEM
    550
    1.35
    27.0
    KCl/Polymer/GEM
    550
    1.03
    1.0
    Seawater
    633
    1.35
    25.0
    KCl/Polymer/GEM
    1109
    1.03
    1.0
    Seawater
    1109
    1.35
    21.0
    KCl/Polymer/GEM
    1750
    1.20
    15.0
    XP-07
    2201
    1.20
    15.0
    XP-07
    2539
    1.20
    14.0
    XP-07
    2913
    1.20
    15.0
    XP-07
  • Palynologiske preparater i Sokkeldirektoratet

    Palynologiske preparater i Sokkeldirektoratet
    Prøve dybde
    Dybde enhet
    Prøve type
    Laboratorie
    620.0
    [m]
    DC
    PETROSTR
    660.0
    [m]
    DC
    PETROS
    700.0
    [m]
    DC
    PETROS
    740.0
    [m]
    DC
    PETROS
    780.0
    [m]
    DC
    PETROS
    820.0
    [m]
    DC
    PETROS
    860.0
    [m]
    DC
    PETROS
    900.0
    [m]
    DC
    PETROS
    940.0
    [m]
    DC
    PETROS
    980.0
    [m]
    DC
    PETROS
    1020.0
    [m]
    DC
    PETROS
    1060.0
    [m]
    DC
    PETROS
    1090.0
    [m]
    DC
    PETROS
    1100.0
    [m]
    DC
    PETROS
    1140.0
    [m]
    DC
    PETROS
    1170.0
    [m]
    DC
    PETROS
    1200.0
    [m]
    DC
    PETROS
    1230.0
    [m]
    DC
    PETROS
    1260.0
    [m]
    DC
    PETROS
    1290.0
    [m]
    DC
    PETROS
    1320.0
    [m]
    DC
    PETROS
    1350.0
    [m]
    DC
    PETROS
    1380.0
    [m]
    DC
    PETROS
    1410.0
    [m]
    DC
    PETROS
    1440.0
    [m]
    DC
    PETROS
    1470.0
    [m]
    DC
    PETROS
    1500.0
    [m]
    DC
    PETROS
    1530.0
    [m]
    DC
    PETROS
    1560.0
    [m]
    DC
    PETROS
    1590.0
    [m]
    DC
    PETROS
    1620.0
    [m]
    DC
    PETROS
    1650.0
    [m]
    DC
    PETROS
    1680.0
    [m]
    DC
    PETROS
    1710.0
    [m]
    DC
    PETROS
    1740.0
    [m]
    DC
    PETROS
    1770.0
    [m]
    DC
    PETROS
    1800.0
    [m]
    DC
    PETROS
    1830.0
    [m]
    DC
    PETROS
    1860.0
    [m]
    DC
    PETROS
    1890.0
    [m]
    DC
    PETROS
    1920.0
    [m]
    DC
    PETROS
    1950.0
    [m]
    DC
    PETROS
    1980.0
    [m]
    DC
    PETROS
    2010.0
    [m]
    DC
    PETROS
    2040.0
    [m]
    DC
    PETROS
    2070.0
    [m]
    DC
    PETROS
    2100.0
    [m]
    DC
    PETROS
    2130.0
    [m]
    DC
    PETROS
    2160.0
    [m]
    DC
    PETROS
    2190.0
    [m]
    DC
    PETROS
    2220.0
    [m]
    DC
    PETROS
    2250.0
    [m]
    DC
    PETROS
    2280.0
    [m]
    DC
    PETROS
    2310.0
    [m]
    DC
    PETROS
    2340.0
    [m]
    DC
    PETROS
    2370.0
    [m]
    DC
    PETROS
    2400.0
    [m]
    DC
    PETROS
    2430.0
    [m]
    DC
    PETROS
    2460.0
    [m]
    DC
    PETROS
    2490.0
    [m]
    DC
    PETROS
    2496.0
    [m]
    DC
    PETROS
    2502.0
    [m]
    DC
    PETROS
    2508.0
    [m]
    DC
    PETROS
    2514.0
    [m]
    DC
    PETROS
    2520.0
    [m]
    DC
    PETROS
    2526.0
    [m]
    DC
    PETROS
    2532.0
    [m]
    DC
    PETROS
    2538.0
    [m]
    DC
    PETROS
    2550.0
    [m]
    DC
    PETROS
    2559.0
    [m]
    DC
    PETROS
    2565.0
    [m]
    DC
    PETROS
    2571.0
    [m]
    DC
    PETROS
    2577.0
    [m]
    DC
    PETROS
    2583.0
    [m]
    DC
    PETROS
    2589.0
    [m]
    DC
    PETROS
    2595.0
    [m]
    DC
    PETROS
    2601.0
    [m]
    DC
    PETROS
    2607.0
    [m]
    DC
    PETROS
    2610.0
    [m]
    DC
    PETROS
    2616.0
    [m]
    DC
    PETROS
    2622.0
    [m]
    DC
    PETROS
    2628.0
    [m]
    DC
    PETROS
    2634.0
    [m]
    DC
    PETROS
    2640.0
    [m]
    DC
    PETROS
    2646.0
    [m]
    DC
    PETROS
    2652.0
    [m]
    DC
    PETROS
    2658.0
    [m]
    DC
    PETROS
    2664.0
    [m]
    DC
    PETROS
    2670.0
    [m]
    DC
    PETROS
    2676.0
    [m]
    DC
    PETROS
    2682.0
    [m]
    DC
    PETROS
    2688.0
    [m]
    DC
    PETROS
    2694.0
    [m]
    DC
    PETROS
    2700.0
    [m]
    DC
    PETROS
    2706.0
    [m]
    DC
    PETROS
    2712.0
    [m]
    DC
    PETROS
    2718.0
    [m]
    DC
    PETROS
    2724.0
    [m]
    DC
    PETROS
    2730.0
    [m]
    DC
    PETROS
    2736.0
    [m]
    DC
    PETROS
    2742.0
    [m]
    DC
    PETROS
    2748.0
    [m]
    DC
    PETROS
    2754.0
    [m]
    DC
    PETROS
    2757.0
    [m]
    DC
    PETROS
    2760.0
    [m]
    DC
    PETROS
    2766.0
    [m]
    DC
    PETROS
    2772.0
    [m]
    DC
    PETROS
    2778.0
    [m]
    DC
    PETROS
    2784.0
    [m]
    DC
    PETROS
    2790.0
    [m]
    DC
    PETROS
    2796.0
    [m]
    DC
    PETROS
    2802.0
    [m]
    DC
    PETROS
    2808.0
    [m]
    DC
    PETROS
    2814.0
    [m]
    DC
    PETROS
    2820.0
    [m]
    DC
    PETROS
    2826.0
    [m]
    DC
    PETROS
    2832.0
    [m]
    DC
    PETROS
    2838.0
    [m]
    DC
    PETROS
    2844.0
    [m]
    DC
    PETROS
    2850.0
    [m]
    DC
    PETROS
    2856.0
    [m]
    DC
    PETROS
    2859.0
    [m]
    DC
    FUGRO
    2862.0
    [m]
    DC
    PETROS
    2868.0
    [m]
    DC
    PETROS
    2880.0
    [m]
    DC
    PETROS
    2892.0
    [m]
    DC
    PETROS
    2904.0
    [m]
    DC
    PETROS
    2912.0
    [m]
    DC
    PETROS