Faktasider Sokkeldirektoratet
Faktasider Sokkeldirektoratet
sodir.no          English
23.11.2024 - 01:30
Tidspunkt for siste synkronisering med Sokkeldirektoratets interne systemer

30/6-28 S

Eksport: PDF ikon PDF
  • Generell informasjon

    Generell informasjon
    Attributt Verdi
    Brønnbane navn
    Offisielt navn på brønnbanen ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    30/6-28 S
    Type
    Brønnbanetype. Lovlige verdier: EXPLORATION, DEVELOPMENT, OTHER (se 'Formål' for mer informasjon)
    EXPLORATION
    Formål
    Endelig klassifisering av brønnbanen.

    Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Lovlige verdier for utvinningsbrønnbaner:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Lovlig verdier for andre brønnbaner:
    SOIL DRILLING (boring ifm trase og andre grunnundersøkelser som gjøres for å undersøke grunnforholdene i forkant av plassering av innretninger),
    SHALLOW GAS (undersøke grunn gass før første boring på lokasjon),
    PILOT (undersøke geologi og væskekontakter for plassering av hovedbrønnbanen),
    SCIENTIFIC (bores ihhtLov om vitenskapelige undersøkelser),
    STRATIGRAPHIC (bores ihht Petroleumsloven §2-1).
    WILDCAT
    Status
    Status for brønnbanen. Lovlige verdier:

    BLOWOUT: Det har vært blowout i brønnen.
    CLOSED: Utvinningsbrønnbane som er stengt for produksjon/injeksjon i kortere eller lengre periode. Statusen er også brukt på ferdig borete brønnbaner, der månedlig produksjon/injeksjon ikke har blitt rapportert enda.
    DRILLING: Brønnen er i borefasen. Kan være i aktiv boring, logging, testing eller plugging.
    JUNKED: Boringen ble avsluttet pga tekniske problemer,
    P&A: For letebrønnbane: brønnbanen er plugget og forlatt, og kan ikke re-entres for videre bruk. For utvinningsbrønnbane: produksjon/injeksjon er avsluttet og brønnen er plugget. Brønnhodet er fjernet eller på annet vis gjort utilgjengelig for nye brønnoperasjoner.
    PLUGGED: Brønnbane som er plugget, men øvre deler av brønnbanen kan brukes til å bore nye sidesteg mot nye boremål.
    PRODUCING: Det ble produsert fra brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    INJECTING: Det ble injisert i brønnbanen ved operatørens siste månedlige innrapportering til Sokkeldirektoratet.
    SUSPENDED: Brønnbane der boringen er midlertidig stoppet. Rettighetshaverne planlegger å fortsette boringen på et senere tidspunkt.
    WILL NEVER BE DRILLED: Brønnbane som er registrert med navn og WellID av Sokkeldirektoratet, men som av ulike årsaker ikke vil bli boret.
    P&A
    Pressemelding
    Flergrensbønn
    Indikator som forteller om brønnbanen er en flergrensbrønn, dvs. har mer enn en gren. Eksempel på lovlige verdier: YES, NO. Se også Sokkeldirektoratets retninglinjer for betegnelse på brønner og brønnbaner.
    NO
    Faktakart i nytt vindu
    Hovedområde
    Navn på området på norsk koninentalsokkel hvor brønnbanen ligger. Lovlige verdier: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    NORTH SEA
    Felt
    Navn på feltet som brønnbanen er relatert til.
    Funn
    Navn på funnet som brønnbanen er relatert til.
    Brønn navn
    Offisielt navn på brønnen som brønnbanen tilhører ihht Sokkeldirektoratets retningslinjer for betegnelse på brønner og brønnbaner.
    30/6-28
    Utvinningstillatelse
    Offisielt navn på utvinningstillatelsen som brønnbanen ble boret eller planlegges boret ut fra (brønnhodeposisjonen).
    Boreoperatør
    Navn på rettighetshaver som på vegne av den aktive utvinningstillatelsen (ved brønnhodeposisjon) starter boreoperasjonen. Dette tilsvarer vanligvis operatørselskapet for den aktuelle utvinningstillatelsen.
    Statoil Petroleum AS
    Boretillatelse
    Boretillatelsesnummer sammen med versjon av boretillatelsen som angitt i boretillatelsen gitt av Sokkeldirektoratet.
    1390-L
    Boreinnretning
    Sokkeldirektoratets navn på innretningen som brønnbanen ble boret fra.
    Boredager
    Antall dager fra borestart til boreslutt.
    74
    Borestart
    Dato borekrona trengte gjennom jordskorpa. For sidesteg: Datoen ny formasjon blir boret, se også utboringsdyp.
    16.01.2012
    Boreslutt
    Letebrønner fra flyttbare innretninger:
    For flytende innretninger - dato når ankerhåndteringen startet.For oppjekkbare innretninger - dato for oppstart av nedjekking.
    Letebrønner fra faste innretninger og alle utvinningsbrønner:
    Dato for når totalt dyp er nådd og siste foringsrør, casing eller screen er satt. Ved umiddelbar plugging av brønnbanen, tilsvarer boreslutt datoen siste plugg er satt.
    29.03.2012
    Frigitt dato
    Dato for når rådata som er innrapportert til myndighetene fra brønnen ikke lenger er undergitt taushetsplikt. Normalt ca 2 år etter boreslutt. Kan være tidligere hvis arealet for utvinningstillatelsen er tilbakelevert.
    29.03.2014
    Publiseringsdato
    Dato kvalitetskontroll av informasjon om brønnbanen ble ferdig, slik at den kan publiseres på internett som en 'Well Data Summary Sheet brønnbane', dvs. med mer informasjon tilgjengelig enn for andre brønnbaner.
    29.03.2014
    Opprinnelig formål
    Formålet med brønnbanen definert før borestart.Lovlige verdier for letebrønnbaner: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Eksempler på lovlige verdier for utvinningsbrønnbaner: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Innhold
    For letebrønnbaner, funn status.

    Lovlige verdier: DRY, SHOWS (spor av hydrokarboner), GAS, GAS/CONDENSATE, OIL eller OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS eller OIL/GAS SHOWS) er oppdaget som fluorescerende kutt (organisk ekstrakt), lukt av petroleum, eller synlig belegg på borekaks eller borekjerner, eller som økte gassavlesninger i slamloggerens detekteringsutstyr.
    Lovlige verdier for WILDCAT-CCS og APPRAISAL-CCS: WATER

    For utvinningsbrønnbaner, type produsert eller injisert fluid.
    Lovlige verdier: WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    OIL
    Funnbrønnbane
    Indikator som forteller om brønnbanen påviste et nytt funn. Lovlige verdier: YES, NO. For brønnbaner der resultatet ikke er pressemeldt eller på annet vis avklart, blir «NO» benyttet.
    YES
    1. nivå med hydrokarboner, alder
    Alder på litostratigrafisk enhet, 1. nivå, hvor petroleum er blitt påvist. Eksempler på lovlige verdier: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EOCENE. Se Sokkeldirektoratets bulletins for mer informasjon.
    EARLY JURASSIC
    1. nivå med hydrokarboner, formasjon.
    Navn på litostratigrafisk enhet, 1. nivå, hvor hydrokarboner er blitt påvist. Vises bare på brønner som er frigitt. Eksempler på lovlige verdier: BASEMENT, COOK FM, EKOFISK FM, HEIMDAL FM, SANDNES FM, SOGNEFJORD FM, TARBERT FM, BRENT GP. Se Sokkeldirektoratets bulletins for mer informasjon.
    STATFJORD GP
    Avstand, boredekk - midlere havflate [m]
    Avstand i meter mellom boredekk og midlere havnivå (RKB).
    25.0
    Vanndybde ved midlere havflate [m]
    Dybde i meter mellom midlere havflate og havbunn.
    110.0
    Totalt målt dybde (MD) [m RKB]
    Målt lengde av brønnbanen fra boredekket til bunnen av brønnbanen ("driller`s depth").
    4064.0
    Totalt vertikalt dybde (TVD) [m RKB]
    Vertikalt dybde fra dypet ved slutten av brønnbanen til boredekket. Vises bare på brønner som er frigitt. Referert til som sant vertikalt dyp (TVD: TrueVerticalDepth).
    3832.0
    Maks inklinasjon [°]
    Maksimum avvik, i grader, fra vertikal brønnbane. Vises bare på brønner som er frigitt.
    31
    Temperatur ved bunn av brønnbanen [°C]
    Estimert temperatur ved bunnen av brønnbanen. Vises bare på brønner som er frigitt. Se beskrivelse.
    140
    Eldste penetrerte alder
    Alder (iflg. Geologic Time Scale 2004 by F. M. Gradstein, et al. (2004)) til den eldste formasjonen det er blitt boret gjennom. Kan avvike fra alder ved TD for eksempel i avviksbrønner. Eksempler for lovlige verdier: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EARLY PERMIAN, EARLY TRIASSIC, EOCENE.
    LATE TRIASSIC
    Eldste penetrerte formasjon
    Navn på den eldste litostratigrafiske enheten som brønnbanen har penetrert. Vises bare på brønner som er frigitt. I de fleste brønnbaner er dette formasjonen eller gruppen påtruffet i bunnen av brønnbanen. Kan avvike fra formasjonen eller gruppen ved TD for eksempel i brønnbaner som er boret med høy avvik eller gjennom forkastninger. Eksempler på lovlige verdier: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, SHETLAND GP.
    HEGRE GP
    Geodetisk datum
    Referansesystem for koordinater. Eksempel på lovlige verdier: ED50.
    ED50
    NS grader
    Geografisk koordinat for brønnhode, nord-sør grader.
    60° 33' 59.47'' N
    ØV grader
    Geografisk koordinat for brønnhode, øst-vest grader.
    2° 44' 40.7'' E
    NS UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, nord-sør.
    6714691.29
    ØV UTM [m]
    Universal Transverse Mercator koodinat for brønnhode, øst-vest.
    486000.09
    UTM sone
    Universal Transverse Mercator sone. Eksempel på lovlige verdier: 31, 32, 33, 34.
    31
    NPDID for brønnbanen
    Sokkeldirektoratets entydige nøkkel for brønnbanen.
    6768
  • Brønnhistorie

    General
    Well 30/6-28 S was drilled in the Oseberg Alpha fault block, the main structure on the Oseberg Field. The primary objective was to test the Crux prospect in the Lomvi Formation in the Triassic Hegre Group. The secondary objective was to test the Crimp prospect in the Statfjord Group in an up flank position of the 30/6-17 well.
    Operations and results
    Due to shallow gas warnings a pilot hole (30/6-U-26) was drilled 15m south of the main well position. The pilot was drilled to 749 m in the Utsira Formation. No shallow gas indications while drilling the pilot and the main well were observed by the ROV or seen on the logs.
    Wildcat well 30/6-28 S was spudded with the semi-submersible installation COSL Pioneer on 16 January 2012 and drilled to TD at 4063 m in Late Triassic sediments in the Hegre Group. The well was drilled vertical down to 1020 m and deviated from there, reaching a ca 30 deg deviation at 2550 m. This deviation was kept down to ca 3850 m, from where the deviation fell back to 19 deg at TD. The well was drilled with sea water and hi-vis pills down to 1010 m, with Versatec oil based mud from 1010 m to 2075 m, and with Low-EDC-HTHP oil based mud from 2075 m to TD.
    Oil was found in the very top of the Statfjord Group with an estimated OWC at 2487.6 m (2453 m TVD) in the well. Due to an unexpected thick "Alke formation" (informal unit) within the Hegre Group the Lomvi Formation was not reached. The whole Triassic sequence was dry. No oil shows were described in the well.
    No cores were cut. MDT fluid samples were taken at 2484.7 m (oil) and 3549 m (water).
    The well was permanently abandoned on 29 March 2012 as an oil discovery.
    Testing
    No drill stem test was performed.
  • Borekaks i Sokkeldirektoratet

    Borekaks i Sokkeldirektoratet
    Borekaks tilgjengelig for prøvetaking?
    YES
    Borekaks i Sokkeldirektoratet
    Borekaksprøve, topp dybde [m]
    Borekaksprøve, bunn dybde [m]
    1020.00
    4063.00
  • Oljeprøver i Sokkeldirektoratet

    Oljeprøver i Sokkeldirektoratet
    Test type
    Flaske nummer
    Topp dyp
    MD [m]
    Bunn dyp
    MD [m]
    Væske type
    Test tidspunkt
    Prøver tilgjengelig
    MDT
    2485.00
    0.00
    OIL
    YES
  • Foringsrør og formasjonsstyrketester

    Foringsrør og formasjonsstyrketester
    Type utforing
    Utforing diam.
    [tommer]
    Utforing dybde
    [m]
    Brønnbane diam.
    [tommer]
    Brønnbane dyp
    [m]
    LOT/FIT slam eqv.
    [g/cm3]
    Type formasjonstest
    CONDUCTOR
    30
    198.5
    36
    202.0
    0.00
    LOT
    SURF.COND.
    20
    1003.0
    26
    1010.0
    1.54
    LOT
    INTERM.
    14
    2068.7
    17 1/2
    2075.0
    1.79
    LOT
    INTERM.
    9 5/8
    3382.0
    12 1/4
    3402.0
    1.78
    LOT
    OPEN HOLE
    4063.0
    8 1/2
    4063.0
    0.00
    LOT
  • Logger

    Logger
    Type logg
    Topp dyp for logg [m]
    Bunn dyp for logg [m]
    CBL GR
    1385
    1940
    CBL VDL GR
    1415
    1993
    GYRO CBL VDL GR
    170
    2022
    GYRO USIT CBL GR
    1781
    3150
    MDT
    2470
    2550
    MDT GR
    3453
    4012
    MWD - ARCVRES9 PP
    202
    1010
    MWD - PDX5 ARCVRES9 TELE
    1010
    2075
    MWD - PDX5 AV8 TE ST VSO8 SADN8
    2075
    3402
    MWD - PDX5 AV8 TEL STET
    3402
    4063
    MWD - POWERPULSE
    135
    202
    PEX AIT MSIP
    3365
    4069
    PEX AIT MSIP
    3382
    3435
    VSP GR
    1755
    4052
  • Litostratigrafi

  • Boreslam

    Boreslam
    Dybde MD [m]
    Egenvekt, slam [g/cm3]
    Viskositet, slam [mPa.s]
    Flytegrense [Pa]
    Type slam
    Dato, måling
    996
    1.23
    20.0
    Versatec
    1013
    1.25
    22.0
    Versatec
    1481
    1.27
    23.0
    Versatec
    1628
    1.54
    37.0
    Versatec
    2018
    1.55
    30.0
    Versatec
    2075
    1.54
    43.0
    Versatec
    2131
    1.38
    12.0
    OBM-Low ECD
    2241
    1.39
    14.0
    OBM-Low ECD
    3080
    1.40
    14.0
    OBM-Low ECD-HTHP
    3129
    1.39
    14.0
    OBM-Low ECD-HTHP
    3317
    1.39
    16.0
    OBM-Low ECD-HTHP
    3402
    1.60
    25.0
    OBM-Low ECD-HTHP
    3405
    1.59
    22.0
    OBM-Low ECD-HTHP
    3781
    1.60
    23.0
    OBM-Low ECD-HTHP
    3800
    1.68
    27.0
    OBM-Low ECD-HTHP
    3800
    1.67
    27.0
    OBM-Low ECD-HTHP
    4063
    1.57
    25.0
    OBM-Low ECD-HTHP
    4063
    1.60
    25.0
    OBM-Low ECD-HTHP
  • Palynologiske preparater i Sokkeldirektoratet

    Palynologiske preparater i Sokkeldirektoratet
    Prøve dybde
    Dybde enhet
    Prøve type
    Laboratorie
    2190.0
    [m]
    DC
    FUGRO
    2200.0
    [m]
    DC
    FUGRO
    2210.0
    [m]
    DC
    FUGRO
    2220.0
    [m]
    DC
    FUGRO
    2230.0
    [m]
    DC
    FUGRO
    2240.0
    [m]
    DC
    FUGRO
    2250.0
    [m]
    DC
    FUGRO
    2260.0
    [m]
    DC
    FUGRO
    2270.0
    [m]
    DC
    FUGRO
    2280.0
    [m]
    DC
    FUGRO
    2290.0
    [m]
    DC
    FUGRO
    2300.0
    [m]
    DC
    FUGRO
    2310.0
    [m]
    DC
    FUGRO
    2320.0
    [m]
    DC
    FUGRO
    2330.0
    [m]
    DC
    FUGRO
    2340.0
    [m]
    DC
    FUGRO
    2350.0
    [m]
    DC
    FUGRO
    2360.0
    [m]
    DC
    FUGRO
    2370.0
    [m]
    DC
    FUGRO
    2380.0
    [m]
    DC
    FUGRO
    2390.0
    [m]
    DC
    FUGRO
    2400.0
    [m]
    DC
    FUGRO
    2410.0
    [m]
    DC
    FUGRO
    2420.0
    [m]
    DC
    FUGRO
    2430.0
    [m]
    DC
    FUGRO
    2440.0
    [m]
    DC
    FUGRO
    2450.0
    [m]
    DC
    FUGRO
    2460.0
    [m]
    DC
    FUGRO
    2470.0
    [m]
    DC
    FUGRO
    2480.0
    [m]
    DC
    FUGRO
    2490.0
    [m]
    DC
    FUGRO
    2500.0
    [m]
    DC
    FUGRO
    2510.0
    [m]
    DC
    FUGRO
    2520.0
    [m]
    DC
    FUGRO
    2530.0
    [m]
    DC
    FUGRO
    2540.0
    [m]
    DC
    FUGRO
    2550.0
    [m]
    DC
    FUGRO
    2560.0
    [m]
    DC
    FUGRO
    2570.0
    [m]
    DC
    FUGRO
    2580.0
    [m]
    DC
    FUGRO
    2600.0
    [m]
    DC
    FUGRO
    2610.0
    [m]
    DC
    FUGRO
    2620.0
    [m]
    DC
    FUGRO
    2630.0
    [m]
    DC
    FUGRO
    2640.0
    [m]
    DC
    FUGRO
    2650.0
    [m]
    DC
    FUGRO
    2660.0
    [m]
    DC
    FUGRO
    2670.0
    [m]
    DC
    FUGRO
    2680.0
    [m]
    DC
    FUGRO
    2690.0
    [m]
    DC
    FUGRO
    2700.0
    [m]
    DC
    FUGRO
    2710.0
    [m]
    DC
    FUGRO
    2720.0
    [m]
    DC
    FUGRO
    2730.0
    [m]
    DC
    FUGRO
    2740.0
    [m]
    DC
    FUGRO
    2750.0
    [m]
    DC
    FUGRO
    2760.0
    [m]
    DC
    FUGRO
    2770.0
    [m]
    DC
    FUGRO
    2780.0
    [m]
    DC
    FUGRO
    2790.0
    [m]
    DC
    FUGRO
    2800.0
    [m]
    DC
    FUGRO
    2810.0
    [m]
    DC
    FUGRO
    2820.0
    [m]
    DC
    FUGRO
    2830.0
    [m]
    DC
    FUGRO
    2840.0
    [m]
    DC
    FUGRO
    2850.0
    [m]
    DC
    FUGRO
    2860.0
    [m]
    DC
    FUGRO
    2870.0
    [m]
    DC
    FUGRO
    2880.0
    [m]
    DC
    FUGRO
    2890.0
    [m]
    DC
    FUGRO
    2900.0
    [m]
    DC
    FUGRO
    2910.0
    [m]
    DC
    FUGRO
    2920.0
    [m]
    DC
    FUGRO
    2930.0
    [m]
    DC
    FUGRO
    2940.0
    [m]
    DC
    FUGRO
    2950.0
    [m]
    DC
    FUGRO
    2960.0
    [m]
    DC
    FUGRO
    2970.0
    [m]
    DC
    FUGRO
    2980.0
    [m]
    DC
    FUGRO
    2990.0
    [m]
    DC
    FUGRO
    3000.0
    [m]
    DC
    FUGRO
    3010.0
    [m]
    DC
    FUGRO
    3020.0
    [m]
    DC
    FUGRO
    3030.0
    [m]
    DC
    FUGRO
    3040.0
    [m]
    DC
    FUGRO
    3050.0
    [m]
    DC
    FUGRO
    3060.0
    [m]
    DC
    FUGRO
    3070.0
    [m]
    DC
    FUGRO
    3080.0
    [m]
    DC
    FUGRO
    3090.0
    [m]
    DC
    FUGRO
    3100.0
    [m]
    DC
    FUGRO
    3110.0
    [m]
    DC
    FUGRO
    3120.0
    [m]
    DC
    FUGRO
    3130.0
    [m]
    DC
    FUGRO
    3140.0
    [m]
    DC
    FUGRO
    3150.0
    [m]
    DC
    FUGRO
    3160.0
    [m]
    DC
    FUGRO
    3170.0
    [m]
    DC
    FUGRO
    3180.0
    [m]
    DC
    FUGRO
    3190.0
    [m]
    DC
    FUGRO
    3200.0
    [m]
    DC
    FUGRO
    3210.0
    [m]
    DC
    FUGRO
    3220.0
    [m]
    DC
    FUGRO
    3230.0
    [m]
    DC
    FUGRO
    3240.0
    [m]
    DC
    FUGRO
    3250.0
    [m]
    DC
    FUGRO
    3260.0
    [m]
    DC
    FUGRO
    3270.0
    [m]
    DC
    FUGRO
    3280.0
    [m]
    DC
    FUGRO
    3290.0
    [m]
    DC
    FUGRO
    3300.0
    [m]
    DC
    FUGRO
    3310.0
    [m]
    DC
    FUGRO
    3320.0
    [m]
    DC
    FUGRO
    3330.0
    [m]
    DC
    FUGRO
    3340.0
    [m]
    DC
    FUGRO
    3350.0
    [m]
    DC
    FUGRO
    3360.0
    [m]
    DC
    FUGRO
    3370.0
    [m]
    DC
    FUGRO
    3380.0
    [m]
    DC
    FUGRO
    3390.0
    [m]
    DC
    FUGRO
    3400.0
    [m]
    DC
    FUGRO
    3408.0
    [m]
    DC
    FUGRO
    3426.0
    [m]
    DC
    FUGRO
    3444.0
    [m]
    DC
    FUGRO
    3462.0
    [m]
    DC
    FUGRO
    3495.0
    [m]
    DC
    FUGRO
    3513.0
    [m]
    DC
    FUGRO
    3531.0
    [m]
    DC
    FUGRO
    3549.0
    [m]
    DC
    FUGRO
    3561.0
    [m]
    DC
    FUGRO
    3567.0
    [m]
    DC
    FUGRO
    3573.0
    [m]
    DC
    FUGRO
    3585.0
    [m]
    DC
    FUGRO
    3606.0
    [m]
    DC
    FUGRO
    3609.0
    [m]
    DC
    FUGRO
    3612.0
    [m]
    DC
    FUGRO
    3624.0
    [m]
    DC
    FUGRO
    3633.0
    [m]
    DC
    FUGRO
    3639.0
    [m]
    DC
    FUGRO
    3645.0
    [m]
    DC
    FUGRO
    3657.0
    [m]
    DC
    FUGRO
    3663.0
    [m]
    DC
    FUGRO
    3669.0
    [m]
    DC
    FUGRO
    3684.0
    [m]
    DC
    FUGRO
    3696.0
    [m]
    DC
    FUGRO
    3705.0
    [m]
    DC
    FUGRO
    3723.0
    [m]
    DC
    FUGRO
    3741.0
    [m]
    DC
    FUGRO
    3759.0
    [m]
    DC
    FUGRO
    3765.0
    [m]
    DC
    FUGRO
    3777.0
    [m]
    DC
    FUGRO
    3789.0
    [m]
    DC
    FUGRO
    3792.0
    [m]
    DC
    FUGRO
    3795.0
    [m]
    DC
    FUGRO
    3798.0
    [m]
    DC
    FUGRO
    3804.0
    [m]
    DC
    FUGRO
    3810.0
    [m]
    DC
    FUGRO
    3813.0
    [m]
    DC
    FUGRO
    3819.0
    [m]
    DC
    FUGRO
    3822.0
    [m]
    DC
    FUGRO
    3825.0
    [m]
    DC
    FUGRO
    3828.0
    [m]
    DC
    FUGRO
    3849.0
    [m]
    DC
    FUGRO
    3855.0
    [m]
    DC
    FUGRO
    3873.0
    [m]
    DC
    FUGRO
    3876.0
    [m]
    DC
    FUGRO
    3888.0
    [m]
    DC
    FUGRO
    3903.0
    [m]
    DC
    FUGRO
    3915.0
    [m]
    DC
    FUGRO
    3921.0
    [m]
    DC
    FUGRO
    3927.0
    [m]
    DC
    FUGRO
    3945.0
    [m]
    DC
    FUGRO
    3957.0
    [m]
    DC
    FUGRO
    3981.0
    [m]
    DC
    FUGRO
    3999.0
    [m]
    DC
    FUGRO
    4017.0
    [m]
    DC
    FUGRO
    4032.0
    [m]
    DC
    FUGRO
    4041.0
    [m]
    DC
    FUGRO
    4044.0
    [m]
    DC
    FUGRO