2/4-22 S
Export: PDF
-
General information
-
Wellbore history
GeneralWell 2/4-22 S was drilled to test the Romeo on the Hidra High adjacent to the King Lear discovery in the North Sea. The primary objective was to prove commercial accumulations of recoverable hydrocarbons within Sandstone of the Rotliegendes Group.Operations and resultsWildcat well 2/4-22 S was spudded with the jack-up installation Mærsk Galant on 10 September 2014 and drilled to TD at 4889 m in the Permian Rotliegendes Group. The 8 1/2" section was drilled under HPHT procedures. No significant problem was encountered in the operations. The well was drilled with seawater down to 298 m, with Glydril mud from 298 m to 1001 m, with Versatec oil based mud from 1001 m to 4358 m, and with WARP oil based mud from 4358 m to TD.Hydrocarbons were found in the Jurassic Ula and Bryne Formations and in the Permian Rotliegendes Group, Auk Formation Equivalent. The hydrocarbons in all reservoir correspond to light oil (density of 0.6 g/cm3). Two source rock sequences are penetrated in the well: the Late Jurassic Mandal-Farsund formations and high-TOC carbonaceous shales of the Bryne Formation. No Triassic rocks were seen in the well. No oil shows above the oil based mud were recorded. High gas response was recorded when drilling the organic rich shales in the Mandal and Farsund formations.No cores were cut in the well. Formation fluid samples were acquired in the reservoir using the MDT. Depth correlation and sampling operations were difficult due to the well conditions and failure of the hydraulic units in the MDT strings. Oil was sampled at 4628 m, 4630.8 m and 4678.5 m. Water was sampled at 4875.6 m.The well was permanently abandoned on 22 February 2015 as an oil discovery.TestingNo drill stem test was performed. -
Cuttings at the Norwegian Offshore Directorate
Cuttings at the Norwegian Offshore Directorate Cuttings available for sampling?YESCuttings at the Norwegian Offshore Directorate Cutting sample, top depth [m]Cutting samples, bottom depth [m]310.004889.50 -
Oil samples at the Norwegian Offshore Directorate
Oil samples at the Norwegian Offshore Directorate Test typeBottle numberTop depth
MD [m]Bottom depth
MD [m]Fluid typeTest timeSamples availableMDT0.000.00OILYESMDT0.000.00OILYESMDT0.000.00OILYES -
Casing and leak–off tests
Casing and leak–off tests Casing typeCasing diam.
[inch]Casing depth
[m]Hole diam.
[inch]Hole depth
[m]LOT/FIT mud eqv.
[g/cm3]Formation test typeCONDUCTOR30289.136298.01.20FITSURF.COND.20454.424467.01.40FITLINER161001.0201001.01.68FIT1001.01001.01.72FITINTERM.13 5/83312.017 1/23322.51.90FITPROD.9 7/84349.412 1/44358.02.25FIT4349.44358.02.23FIT4349.54358.02.15LOTOPEN HOLE4889.58 1/24889.50.00 -
Logs
Logs Log typeLog top depth [m]Log bottom depth [m]ABG EWR - P4 DGR PWD DIR10013411CBL USIT34854247DGR EWR - P4 PWD DIR2981001DGR EWR - P4 PWD DIR34114358DGR EWR - P4 PWD GEOTAP ALD CTN43624826DGR EWR - P4 PWD GEOTAP DIR00GR CMR45364885GR MDT46004872GR MDT IFA MRMS45964710GR MDT IFA MRMS46284680GR MDT IFA MRMS46784875GR MDT IFA MRMS48304874GR VSP24374890GR XLROCK46254846HLDS APS ECS GR43504890QAIT ILE DOBMI PPC MSIP PPC43004889USIT CBL9003297 -
Lithostratigraphy
Lithostratigraphy Top depth [mMD RKB]Lithostrat. unit11511517901790306530653074310031473267328632863405384242374237426343044419441944304543456745674622474348304830 -
Drilling mud
Drilling mud Depth MD [m]Mud weight [g/cm3]Visc. [mPa.s]Yield point [Pa]Mud typeDate measured01.4525.0Glydril02.0452.0WARP (Oil Based)1521.6240.0Versatec2981.4525.0Glydril3041.5438.0Versatec3061.1011.0Glydril3181.5438.0Versatec3251.1012.0Glydril3671.5340.0Versatec3751.1318.0Glydril4301.1014.0Glydril4601.2015.0Glydril6371.1513.0Glydril10001.1812.0Glydril18671.6651.0Versatec25911.6662.0Versatec30181.6650.0Versatec40801.7243.0Versatec42002.0444.0WARP (Oil Based)42201.5028.0Versatec42302.0440.0WARP (Oil Based)42631.7542.0Versatec42912.0245.0WARP (Oil Based)43181.7544.0Versatec43192.0242.0WARP (Oil Based)43581.7944.0Versatec43582.0445.0Versatec43581.5825.0Versatec44002.0644.0WARP (Oil Based)47682.0239.0WARP (Oil Based)48042.1637.0WARP (Oil Based)48262.0832.0WARP (Oil Based)48372.0237.0WARP (Oil Based)48892.0440.0WARP (Oil Based)48902.0628.0WARP (Oil Based)