Factpages Norwegian Offshore Directorate
Factpages Norwegian Offshore Directorate
sodir.no          Norsk
22.12.2024 - 01:25
Time of last synchronization with Norwegian Offshore Directorate's internal systems

6407/7-9 S

Export: PDF icon PDF
  • General information

    General information
    Attribute Value
    Wellbore name
    Official name of wellbore based on Norwegian Offshore Directorate guidelines for designation of wells and wellbores.
    6407/7-9 S
    Type
    Wellbore type. Legal values: EXPLORATION, DEVELOPMENT, OTHER (see 'Purpose' for more information)
    EXPLORATION
    Purpose
    Final classification of the wellbore.

    Legal values for exploration wellbores:
    WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS.

    Legal values for development wellbores:
    OBSERVATION, PRODUCTION, INJECTION, INJECTION-CCS, OBSERVATION-CCS.

    Legal values for other wellbores:
    SOIL DRILLING (drilling in connection with track surveys and other subsurface surveys to investigate the soil conditions prior to placement of facilities),
    SHALLOW GAS (drilling to investigate shallow gas before the first 'real' drilling on the location),
    PILOT (drilling to investigate the geology and fluid connectors for location of the main wellbore),
    SCIENTIFIC (drilling according to Law of Scientific research and exploration),
    STRATIGRAPHIC (driling according to Law of Petroleum activities §2-1).
    WILDCAT
    Status
    Status for the wellbore. Legal values are:

    BLOWOUT: A blowout has occurred in the well.
    CLOSED: A development wellbore that has been closed in a shorter or longer periode. Also applies to development wellbores where drilling is completed, but production/injection has not yet been reported.
    DRILLING: The well is in the drilling phase - can be active drilling, logging, testing or plugging,
    JUNKED: The drilling operation has been terminated due to technical problems.
    P&A: Exploration: The well is plugged and abandoned, and can not be reentered for further use. Development wells: The production/injection from/to the well is stopped and the well is plugged. The wellhead is removed or else made unavailable for further well operations.
    PLUGGED: The wellbore has been plugged, but the upper parts of the wellbore can be re-used. A sidetrack might be drilled at a later stage.
    PRODUCING: It was produced from the wellbore at the time of the operators last monthly report to the Norwegian Offshore Directorate.
    INJECTING: It was injected to the wellbore at the time of the operators last monthly report to the Norwegian Offshore Directorate.
    PREDRILLED: The upper part of the well has been drilled, usually as part of a batch-drilling campaign covering several wellbores.
    RE-CLASS TO DEV: Exploration wellbore that is reclassified to a development wellbore.
    RE-CLASS TO TEST: Exploration wellbore that is reclassified to test production.
    SUSPENDED: The drilling operation in the wellbore has been temporarily stopped. The current plan is to continue drilling later on.
    P&A
    Press release
    Multilateral
    Indicator telling if the parent well is multilateral, meaning it has more than one branch radiating from the main borehole. Example of legal values: YES, NO. See also Norwegian Offshore Directorate guidelines for designation of wells and wellbores.
    NO
    Factmaps in new window
    Main area
    Name of the area on the Norwegian Continental Shelf where the wellbore is located. Legal values: BARENTS SEA, NORWEGIAN SEA, NORTH SEA.
    NORWEGIAN SEA
    Discovery
    Name of the discovery the wellbore is related to.
    Well name
    Official name of the parent well for the wellbore based on Norwegian Offshore Directorate guidelines for designation of wells and wellbores.
    6407/7-9
    Production licence
    Official designation of the production licence the wellbore was drilled or planned to be drilled from ( well head posistion).
    Drilling operator
    Name of the licensee starting the drilling operation on behalf of the active production license (well head position). This will usually equal the operator of the production license.
    Statoil Petroleum AS
    Drill permit
    The drilling permit number together with the version of the drilling permit as stated in the drilling permit granted by the Norwegian Offshore Directorate.
    1636-L
    Drilling facility
    Norwegian Offshore Directorate's name of the facility which the wellbore was drilled from.
    Drilling days
    Number of days from wellbore entry to wellbore completion.
    36
    Entered date
    The date when he wellbore was spudded. For sidetracks: The date when new formation was drilled by kicking off from the mother-wellbore,
    15.08.2016
    Completed date
    Exploration wellbores from moveable facilities:
    For floating facilities - date when anchor handling is started. For jackups - date the jacking-down started. Exploration wellbores from fixed facilities and all development wellbores:
    Date when the wellbore is at total depth, and last casing, liner or screen is set. In case of immediate plugging of the wellbore, completed date equals the date the last plug i set in the wellbore.
    Date when the wellbore is at total depth, and last casing, liner or screen is set. In case of immediate plugging of the wellbore, completed date equals the date the last plug i set in the wellbore.
    20.09.2016
    Release date
    Date when raw data which has been reported to the authorities from the wellbore is not confidential any longer. Normally 2 years after finishing the drilling. May be earlier if the area of the production license is relinquished.
    20.09.2018
    Publication date
    Date quality control of the wellbore information was completed, so it can be published on the internet as a 'Well Data Summary Sheet' wellbore with more information available than other wellbores.
    20.09.2018
    Purpose - planned
    Pre-drill purpose of the wellbore. Legal values for exploration wellbores: WILDCAT, APPRAISAL, WILDCAT-CCS, APPRAISAL-CCS. Example of legal values for development wellbores: OBSERVATION, PRODUCTION, INJECTION.
    WILDCAT
    Content
    For exploration wellbores, status of discovery.

    Legal values:
    DRY, SHOWS (trace amounts of hydrocarbons), GAS, GAS/CONDENSATE, OIL or OIL/GAS.
    SHOWS (GAS SHOWS, OIL SHOWS or OIL/GAS SHOWS) are detected as fluorescent cut (organic extract), petroleum odour, or visual stain on cuttings or cores, or as increased gas reading on the mud-loggers gas detection equipment.
    Legal values for WILDCAT-CCS and APPRAISAL-CCS: WATER

    For development wellbores, type of produced/injected fluid.
    Legal values:
    WATER, CUTTINGS, NOT AVAILABLE, OIL, GAS/CONDENSATE, OIL/GAS, CO2, GAS, WATER/GAS, NOT APPLICABLE.
    OIL/GAS/CONDENSATE
    Discovery wellbore
    Indicator which tells if the wellbore made a new discovery. Legal values: YES, NO. Prior to press-release or other information regarding drilling results, the indicator will be “NO” as a default.
    YES
    1st level with HC, age
    Age of lithostratigraphic unit, 1st level, where hydrocarbons were encountered. Examples of legal values: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EOCENE. See also Norwegian Offshore Directorate bulletins.
    EARLY JURASSIC
    1st level with HC, formation
    Name of lithostartigraphic unit, 1st level, where hydrocarbons were encountered. Shown only for released wells. Examples of legal values: BASEMENT, COOK FM, EKOFISK FM, HEIMDAL FM, SANDNES FM, SOGNEFJORD FM, TARBERT FM, BRENT GP. See also Norwegian Offshore Directorate bulletins.
    TILJE FM
    2nd level with HC, age
    Age of lithostratigraphic unit, 2nd level, where hydrocarbons were encountered. Examples of legal values: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EOCENE.
    MIDDLE JURASSIC
    2nd level with HC, formation
    Name of lithostartigraphic unit, 2nd level, where hydrocarbons were encountered. Shown only for released wells. Examples of legal values: BASEMENT, COOK FM, EKOFISK FM, HEIMDAL FM, SANDNES FM, SOGNEFJORD FM, TARBERT FM, BRENT GP.
    ILE FM
    3rd level with HC, age
    Age of lithostratigraphic unit, 3rd level, where hydrocarbons were encountered. Examples of legal values: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EOCENE.
    CRETACEOUS
    3rd level with HC, formation
    Name of lithostartigraphic unit, 3rd level, where hydrocarbons were encountered. Shown only for released wells. Examples of legal values: BASEMENT, COOK FM, EKOFISK FM, HEIMDAL FM, SANDNES FM, SOGNEFJORD FM, TARBERT FM, BRENT GP.
    LANGE FM
    Kelly bushing elevation [m]
    Elevation of the rotary kelly bushing (RKB) above mean sea level.
    29.0
    Water depth [m]
    Depth in metres betweem mean sea level and sea floor.
    323.0
    Total depth (MD) [m RKB]
    Total measured length of wellbore from kelly bushing to total depth (driller's depth).
    4143.0
    Final vertical depth (TVD) [m RKB]
    Vertical elevation from total depth to kelly bushing. Shown only for released wells. Referred to as true vertical depth (TVD).
    4134.0
    Maximum inclination [°]
    Maximum deviation, in degrees, from a vertical well path.Shown only for released wells.
    9.7
    Bottom hole temperature [°C]
    Estimated temperature at final total depth of the wellbore. Shown only for released wells. See discription.
    153
    Oldest penetrated age
    Age (according to Geologic Time Scale 2004 by F. M. Gradstein, et al. (2004)) of the oldest penetrated formation. May differ from age at TD for example in deviated wellbores. Examples of legal values: CRETACEOUS, EARLY CRETACEOUS, LATE JURASSIC, EARLY PERMIAN, EARLY TRIASSIC, EOCENE.
    EARLY JURASSIC
    Oldest penetrated formation
    Name of the oldest lithostratigraphic unit penetrated by the wellbore. Shown only for released wells. In most wellbores this is formation or group at total depth. May differ from formation or group at TD for example in wellbores drilled with high deviation or through faults. Examples of legal values: AMUNDSEN FM, BALDER FM, BASEMENT, BLODØKS FM, BRYNE FM, BURTON FM, COOK FM, DRAKE FM, DRAUPNE FM, EKOFISK FM, DUNLIN GP.
    ÅRE FM
    Geodetic datum
    Reference system for coordinates. Example of legal values: ED50.
    ED50
    NS degrees
    Geographic coordinate of the wellhead, north-south degrees.
    64° 18' 59.25'' N
    EW degrees
    Geographic coordinate of the wellhead, east-west degrees.
    7° 9' 24.4'' E
    NS UTM [m]
    Universal Transverse Mercator coordinate of the wellhead, north-south.
    7133747.71
    EW UTM [m]
    Universal Transverse Mercator coordinate of the wellhead, east-west.
    410870.09
    UTM zone
    Universal Transverse Mercator zone. Examples of legal values: 31, 32, 33, 34.
    32
    NPDID wellbore
    Norwegian Offshore Directorate's unique id for the wellbore.
    8029
  • Wellbore history

    General
    Well 6407/7-9 S was drilled to test the Njord North Flank 2 prospect about 6 km north of the producing Njord Field in the Norwegian Sea. The primary objective was to prove hydrocarbon potential in the Early-Middle Jurassic Tilje and Ile formations. The secondary objective was to test the hydrocarbon potential in the Åre Formation.
    Operations and results
    Wildcat well 6407/7-9 S was spudded with the semi-submersible installation Songa Delta on 15 August 2016 and drilled to TD at 4143 m (4134 m TVD) m in the Early Jurassic Åre Formation. Drilling to TD proceeded without significant problems, but during P&A and preparing for sidetracking pulling of the 9 5/8" casing hanger caused severe problems and four days NPT. The well was drilled with seawater and hi-vis pills down to 1175 m and with XP07 oil based mud from 1175 m to TD.
    Top of the primary reservoir targets, the Ile Formation was reached at 3623 m (3614.8 m TVD). A 102-metre oil column was encountered in the Ile formation, and a 157-metre gas/condensate column in the Tilje Formation. The reservoir properties in both reservoirs are poor to moderate. The well did not encounter a reservoir in the Åre formation. A few thin sand layers were encountered in the Early Cretaceous Lange formation, some with petroleum, but with poor reservoir properties. An oil-water contact in the Ile Formation at 3727 m (3719 m TVD) was established based on logs and sampling. Otherwise, all hydrocarbon columns were in oil down-to situations. No shows were observed outside of the hydrocarbon-bearing reservoirs
    Two cores were cut. Ile was cored from 3636 to 3690 m with 100% recovery. Tilje was cored from 3901 to 4010 m with 100% recovery. MDT fluid samples were taken in the Ile Formation at 3641.8 m (oil), 3725.4 m (oil), 3729 m (water), and in the Tilje Formation at 3916 m (gas condensate) and at 4017.2 m (gas condensate). Isotubes to collect further gas, including in the Lange Formation, proved to contain only air and no formation gas.
    The wellbore was plugged back for sidetracking on 20 September 2016. It is classified as an oil/gas/condensate discovery.
    Testing
    No drill stem test was performed.
  • Cuttings at the Norwegian Offshore Directorate

    Cuttings at the Norwegian Offshore Directorate
    Cuttings available for sampling?
    YES
    Cuttings at the Norwegian Offshore Directorate
    Cutting sample, top depth [m]
    Cutting samples, bottom depth [m]
    1190.00
    4143.00
  • Cores at the Norwegian Offshore Directorate

    Cores at the Norwegian Offshore Directorate
    Core sample number
    Core sample - top depth
    Core sample - bottom depth
    Core sample depth - uom
    1
    3636.0
    3690.8
    [m ]
    2
    3901.0
    4009.8
    [m ]
    Cores at the Norwegian Offshore Directorate
    Total core sample length [m]
    163.6
    Cores at the Norwegian Offshore Directorate
    Cores available for sampling?
    YES
  • Casing and leak–off tests

    Casing and leak–off tests
    Casing type
    Casing diam.
    [inch]
    Casing depth
    [m]
    Hole diam.
    [inch]
    Hole depth
    [m]
    LOT/FIT mud eqv.
    [g/cm3]
    Formation test type
    CONDUCTOR
    30
    402.0
    36
    403.0
    0.00
    SURF.COND.
    13 3/8
    1175.0
    17 1/2
    1183.0
    0.00
    1213.0
    0.0
    1.61
    FIT
    INTERM.
    9 5/8
    3102.0
    12 1/4
    3111.0
    1.91
    LOT
    OPEN HOLE
    4143.0
    8 1/2
    4143.0
    0.00
  • Logs

    Logs
    Log type
    Log top depth [m]
    Log bottom depth [m]
    AIT PEX MSIP ECS
    3102
    4138
    MDT HC MINIDST
    3260
    4065
    MDT PP CMR
    3260
    4064
    MWD - ARC6 TELE675
    3636
    4143
    MWD - ARC9 TELE
    402
    1183
    MWD - PDX5 ARC9 TELE
    1183
    3636
    MWD - TELE
    352
    402
    SWC XL ROCK
    3260
    4066
    SWC XL ROCK
    3866
    4064
    ZOVSP
    940
    4130
  • Lithostratigraphy

  • Drilling mud

    Drilling mud
    Depth MD [m]
    Mud weight [g/cm3]
    Visc. [mPa.s]
    Yield point [Pa]
    Mud type
    Date measured
    1115
    1.57
    26.0
    XP-07
    1120
    1.54
    24.0
    XP-07
    1183
    1.39
    20.0
    XP-07
    1303
    1.45
    27.0
    XP-07
    1782
    1.54
    35.0
    XP-07
    2275
    1.54
    33.0
    XP-07
    2639
    1.54
    27.0
    XP-07
    2922
    1.34
    20.0
    XP-07
    2922
    1.54
    24.0
    XP-07
    2922
    1.60
    34.0
    XP-07
    3111
    1.60
    27.0
    XP-07
    3111
    1.54
    23.0
    XP-07
    3139
    1.60
    34.0
    XP-07
    3596
    1.60
    25.0
    XP-07
    3881
    1.60
    30.0
    XP-07
    4010
    1.60
    28.0
    XP-07
    4143
    1.60
    32.0
    XP-07
  • Palynological slides at the Norwegian Offshore Directorate

    Palynological slides at the Norwegian Offshore Directorate
    Sample depth
    Depth unit
    Sample type
    Laboratory
    1190.0
    [m]
    DC
    APT
    1230.0
    [m]
    DC
    APT
    1270.0
    [m]
    DC
    APT
    1310.0
    [m]
    DC
    APT
    1350.0
    [m]
    DC
    APT
    1390.0
    [m]
    DC
    APT
    1420.0
    [m]
    DC
    APT
    1470.0
    [m]
    DC
    APT
    1510.0
    [m]
    DC
    APT
    1550.0
    [m]
    DC
    APT
    1590.0
    [m]
    DC
    APT
    1630.0
    [m]
    DC
    APT
    1670.0
    [m]
    DC
    APT
    1710.0
    [m]
    DC
    APT
    1750.0
    [m]
    DC
    APT
    1790.0
    [m]
    DC
    APT
    1830.0
    [m]
    DC
    APT
    1870.0
    [m]
    DC
    APT
    1910.0
    [m]
    DC
    APT
    1950.0
    [m]
    DC
    APT
    1990.0
    [m]
    DC
    APT
    2030.0
    [m]
    DC
    APT
    2070.0
    [m]
    DC
    APT
    2110.0
    [m]
    DC
    APT
    2150.0
    [m]
    DC
    APT
    2190.0
    [m]
    DC
    APT
    2230.0
    [m]
    DC
    APT
    2270.0
    [m]
    DC
    APT
    2350.0
    [m]
    DC
    APT
    2390.0
    [m]
    DC
    APT
    2430.0
    [m]
    DC
    APT
    2470.0
    [m]
    DC
    APT
    2510.0
    [m]
    DC
    APT
    2550.0
    [m]
    DC
    APT
    2590.0
    [m]
    DC
    APT
    2630.0
    [m]
    DC
    APT
    2670.0
    [m]
    DC
    APT
    2710.0
    [m]
    DC
    APT
    2750.0
    [m]
    DC
    APT
    2790.0
    [m]
    DC
    APT
    2830.0
    [m]
    DC
    APT
    2870.0
    [m]
    DC
    APT
    2910.0
    [m]
    DC
    APT
    2950.0
    [m]
    DC
    APT
    2990.0
    [m]
    DC
    APT
    3030.0
    [m]
    DC
    APT
    3070.0
    [m]
    DC
    APT
    3110.0
    [m]
    DC
    APT
    3150.0
    [m]
    DC
    APT
    3190.0
    [m]
    DC
    APT
    3220.0
    [m]
    DC
    APT
    3240.0
    [m]
    DC
    APT
    3260.0
    [m]
    DC
    APT
    3264.0
    [m]
    SWC
    APT
    3280.0
    [m]
    DC
    APT
    3300.0
    [m]
    DC
    APT
    3320.0
    [m]
    DC
    APT
    3340.0
    [m]
    DC
    APT
    3360.0
    [m]
    DC
    APT
    3380.0
    [m]
    DC
    APT
    3400.0
    [m]
    DC
    APT
    3423.0
    [m]
    DC
    APT
    3444.0
    [m]
    DC
    APT
    3459.0
    [m]
    DC
    APT
    3465.0
    [m]
    DC
    APT
    3471.0
    [m]
    DC
    APT
    3477.0
    [m]
    DC
    APT
    3483.0
    [m]
    DC
    APT
    3489.0
    [m]
    DC
    APT
    3495.0
    [m]
    DC
    APT
    3501.0
    [m]
    DC
    APT
    3507.0
    [m]
    DC
    APT
    3513.0
    [m]
    DC
    APT
    3519.0
    [m]
    DC
    APT
    3525.0
    [m]
    DC
    APT
    3531.0
    [m]
    DC
    APT
    3537.0
    [m]
    DC
    APT
    3543.0
    [m]
    DC
    APT
    3549.0
    [m]
    DC
    APT
    3555.0
    [m]
    DC
    APT
    3561.0
    [m]
    DC
    APT
    3567.0
    [m]
    DC
    APT
    3573.0
    [m]
    DC
    APT
    3579.0
    [m]
    DC
    APT
    3585.0
    [m]
    DC
    APT
    3591.0
    [m]
    DC
    APT
    3597.0
    [m]
    DC
    APT
    3603.0
    [m]
    DC
    APT
    3609.0
    [m]
    DC
    APT
    3615.0
    [m]
    DC
    APT
    3618.0
    [m]
    DC
    APT
    3624.0
    [m]
    DC
    APT
    3624.0
    [m]
    SWC
    APT
    3630.0
    [m]
    DC
    APT
    3636.0
    [m]
    DC
    APT
    3638.6
    [m]
    C
    APT
    3641.6
    [m]
    C
    APT
    3643.6
    [m]
    C
    APT
    3646.8
    [m]
    C
    APT
    3648.2
    [m]
    C
    APT
    3651.8
    [m]
    C
    APT
    3655.1
    [m]
    C
    APT
    3659.0
    [m]
    C
    APT
    3662.3
    [m]
    C
    APT
    3665.7
    [m]
    C
    APT
    3667.6
    [m]
    C
    APT
    3672.0
    [m]
    C
    APT
    3672.4
    [m]
    C
    APT
    3675.9
    [m]
    C
    APT
    3678.6
    [m]
    C
    APT
    3682.9
    [m]
    C
    APT
    3686.3
    [m]
    C
    APT
    3689.4
    [m]
    C
    APT
    3690.0
    [m]
    DC
    APT
    3690.5
    [m]
    C
    APT
    3696.0
    [m]
    DC
    APT
    3702.0
    [m]
    DC
    APT
    3708.0
    [m]
    DC
    APT
    3714.0
    [m]
    DC
    APT
    3720.0
    [m]
    DC
    APT
    3726.0
    [m]
    DC
    APT
    3732.0
    [m]
    DC
    APT
    3738.0
    [m]
    DC
    APT
    3744.0
    [m]
    DC
    APT
    3750.0
    [m]
    DC
    APT
    3756.0
    [m]
    DC
    APT
    3762.0
    [m]
    DC
    APT
    3768.0
    [m]
    DC
    APT
    3774.0
    [m]
    DC
    APT
    3780.0
    [m]
    DC
    APT
    3786.0
    [m]
    DC
    APT
    3792.0
    [m]
    DC
    APT
    3798.0
    [m]
    DC
    APT
    3804.0
    [m]
    DC
    APT
    3810.0
    [m]
    DC
    APT
    3816.0
    [m]
    DC
    APT
    3822.0
    [m]
    DC
    APT
    3828.0
    [m]
    DC
    APT
    3834.0
    [m]
    DC
    APT
    3840.0
    [m]
    DC
    APT
    3846.0
    [m]
    DC
    APT
    3852.0
    [m]
    DC
    APT
    3855.0
    [m]
    DC
    APT
    3861.0
    [m]
    DC
    APT
    3867.0
    [m]
    DC
    APT
    3873.0
    [m]
    DC
    APT
    3879.0
    [m]
    DC
    APT
    3885.0
    [m]
    DC
    APT
    3891.0
    [m]
    DC
    APT
    3897.0
    [m]
    DC
    APT
    3902.8
    [m]
    C
    APT
    3907.0
    [m]
    C
    APT
    3909.6
    [m]
    C
    APT
    3911.6
    [m]
    C
    APT
    3914.5
    [m]
    C
    APT
    3917.8
    [m]
    C
    APT
    3920.9
    [m]
    C
    APT
    3924.4
    [m]
    C
    APT
    3927.1
    [m]
    C
    APT
    3930.9
    [m]
    C
    APT
    3933.8
    [m]
    C
    APT
    3934.7
    [m]
    C
    APT
    3937.4
    [m]
    C
    APT
    3942.6
    [m]
    C
    APT
    3945.3
    [m]
    C
    APT
    3947.1
    [m]
    C
    APT
    3950.8
    [m]
    C
    APT
    3954.5
    [m]
    C
    APT
    3956.4
    [m]
    C
    APT
    3960.8
    [m]
    C
    APT
    3963.9
    [m]
    C
    APT
    3965.7
    [m]
    C
    APT
    3969.6
    [m]
    C
    APT
    3970.1
    [m]
    C
    APT
    3973.7
    [m]
    C
    APT
    3977.2
    [m]
    C
    APT
    3981.9
    [m]
    C
    APT
    3983.2
    [m]
    C
    APT
    3985.3
    [m]
    C
    APT
    3989.9
    [m]
    C
    APT
    3992.8
    [m]
    C
    APT
    3995.4
    [m]
    C
    APT
    3999.6
    [m]
    C
    APT
    4001.7
    [m]
    C
    APT
    4003.7
    [m]
    C
    APT
    4008.7
    [m]
    C
    APT
    4011.0
    [m]
    DC
    APT
    4017.0
    [m]
    DC
    APT
    4023.0
    [m]
    DC
    APT
    4029.0
    [m]
    DC
    APT
    4035.0
    [m]
    DC
    APT
    4041.0
    [m]
    DC
    APT
    4047.0
    [m]
    DC
    APT
    4053.0
    [m]
    DC
    APT
    4059.0
    [m]
    DC
    APT
    4065.0
    [m]
    DC
    APT
    4071.0
    [m]
    DC
    APT
    4080.0
    [m]
    DC
    APT
    4086.0
    [m]
    DC
    APT
    4092.0
    [m]
    DC
    APT
    4098.0
    [m]
    DC
    APT
    4107.0
    [m]
    DC
    APT
    4113.0
    [m]
    DC
    APT
    4119.0
    [m]
    DC
    APT
    4125.0
    [m]
    DC
    APT
    4131.0
    [m]
    DC
    APT
    4137.0
    [m]
    DC
    APT
    4143.0
    [m]
    DC
    APT